2. The pool heater(s), if located on a combustible floor, shall not require a separate combustible

floor base.

3. The pool heater(s) shall have the option of venting the flue products either through the top or

the back of the unit.

4. Combustion air intake shall be on the left side of the cabinet, right side optional.

L. Manual

Bypass

1.

The pool heater(s) shall be configured with an external bronze pump and bypass
arrangement designed to maintain the water entering the heater at the proper temperature
that will prevent condensation and scale in the heat exchanger. The entire waterway shall be
non-ferrous.

Specifier Note: The remaining items in this section are options. Delete those that are not being

specified. The Low Gas Supply Pressure and FlexGas Manifolds also cannot be used
on the same boiler.

M. Pool Heater Pump - Refer to Equipment Schedule
N. SureRack™ Pool Heater Stacking Kit

1. The pool heaters shall be stacked directly one on top of the other, without offset, to minimize

footprint.

O. Cold Water Run System

1. The pool heater(s) shall be configured with a cold water run automatic proportional by-pass

system that ensures the pool heater will experience inlet temperatures in excess of 105ºF in
less than 7 minutes to avoid damaging condensation. The unit will automatically shut down if
the inlet temperature is not achieved within the 7 minute time frame.

2. The cold water run system shall be configured with a variable speed pump that is controlled by

a system-matched PID control that injects the correct amount of cold water directly into the
pool heater loop to maintain a minimum inlet temperature. The PID controller temperature
sensor shall be located in the inlet header of the pool heater.

3. The control shall have a temperature setting dial located on the face of the board. The

temperature range of the dial shall be 105ºF to 120ºF. The PID Logic shall be capable of
limiting system overshoot to a maximum of 10ºF on initial start-up or call-for-heat.

4. The cold water run system shall be completely wired and mounted at the factory.
5. The control shall have the following diagnostic LED’s:

a. Call for heat
b. Start-up mode
c. Inlet temperature error
d. Sensor out of range

6. The controller shall have alarm contacts.

P. Low Gas Supply Pressure Manifold

1. The pool heater(s) shall be CSA certified for full-input operation down to 4.0 inches W.C.

dynamic inlet gas supply pressure.

Q. Flexgas™ Dual-Fuel Gas Manifold

1. The pool heater(s) shall be configured with a patented, CSA-certified gas control system that

is capable of operating with natural gas or propane gas in a configuration that does not require
mechanical disassembly or adjustment of gas or air components.
a. The gas switching shall be accomplished by a keyed three-position electrical switch with an

“OFF” position between the Natural and Propane settings including a positive fuel
shutdown in both directions to block back-pressure.

b. The FlexGas manifold shall as a minimum have two ON/OFF solenoid shutoff valves for

natural gas, and a minimum of one ON/OFF solenoid shutoff valve and a lock-up regulator
for propane gas, as a safety feature.

c. The FlexGas manifold shall be capable of accomplishing the fuel changeover in less than

sixty seconds.

R. TruSeal™ Direct Vent

1. The pool heater(s) shall meet safety standards for direct vent equipment as noted by the 2006

UMC, section 1107.6, ASHRAE 15-1994, section 8.13.6, and ANSI Z21.56/CSA 4.7.