Maintenance instructions, Glass gasket, General vent maintenance – Regency L900E-NG User Manual
Page 36: Log replacement, Door glass, Glass replacement, Maintenance

Regency
®
L900E Direct Vent Gas Fireplace
36
MAINTENANCE
MAINTENANCE
MAINTENANCE
INSTRUCTIONS
1) Always turn off the unit before cleaning. For
relighting, refer to lighting instructions. Keep 
the burner and control compartment clean 
by brushing and vacuuming at least once 
a year. When cleaning the logs, use a soft 
clean paint brush as the logs are fragile and 
easily damaged.
2) Clean appliance and door with a damp
cloth (never when unit is hot). Never use 
an abrasive cleaner. The glass should be 
cleaned with a gas fi replace glass cleaner. 
The glass should be cleaned when it 
starts looking cloudy.
3) The heater is fi nished in a heat resistant
paint and should only be refi nished with heat 
resistant paint. Regency
®
uses StoveBright
Paint - Metallic Black #6309.
4) Make a periodic check of burner for proper
position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call a qualifi ed service 
person. 
5) The appliance and venting system must be
inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6) Do not use this appliance if any part has been
under water. Immediately call a qualifi ed 
service technician to inspect the appliance 
and to replace any part of the control system 
and any gas control which has been under 
water.
7) In the event this appliance has been
serviced check that the vent-air system 
has been properly resealed & reinstalled 
in accordance with the manufacturer's 
instructions.
8) Verify operation after servicing.
GLASS GASKET
 
If the glass gasket requires replacement use a 
tadpole glass gasket (Part # 936-155). 
 
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system 
semiannually. Recommended areas to inspect 
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements. 
These will appear as rust spots or 
streaks, and in extreme cases, holes. 
These components should be replaced 
immediately.
2) Remove the Cap, and shine a fl ashlight
down the Vent. Remove any bird nests, or 
other foreign material.
3) Check for evidences of excessive
condensation, such as water droplets forming 
in the inner liner, and subsequently dripping 
out the joints, Continuous condensation can 
cause corrosion of caps, pipe, and fi ttings. 
It may be caused by having excessive 
lateral runs, too many elbows, and exterior 
portions of the system being exposed to 
cold weather.
4) Inspect joints, to verify that no pipe
sections or fi ttings have been disturbed, 
and consequently loosened. Also check 
mechanical supports such as Wall Straps, 
or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the unit and allow the unit to cool before 
opening door and carefully remove the logs. If 
for any reason a log should need replacement, 
you must use the proper replacement log. The 
position of these logs must be as shown in the 
diagrams under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will 
severely alter the unit's performance 
w h i c h i s n o t c o v e r e d u n d e r 
warranty.
CAUTION: Wear gloves when 
removing damaged or broken 
glass.
WARNING: Do not operate the 
appliance with the glass panels 
removed, cracked or broken. 
Replacement of the glass panels 
should be done by a licensed or 
qualifi ed service person.
DOOR GLASS
Your Regency
®
fi replace is supplied with high
temperature 5mm-Ceramic glass. If your glass 
requires cleaning, we recommend using an 
approved glass cleaner available at all authorized 
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product 
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fi replace without the 
glass front or with a cracked or broken glass 
front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panel(s) should be
done by a licensed or qualifi ed service per 
son.
GLASS REPLACEMENT
In the event that you break your glass by impact, 
purchase your replacement from an authorized 
Regency
®
dealer only.
Replacement glass is shipped already installed 
into the door frame. 