Installation, Rigid pipe venting systems, Inst alla tion – Regency L900E-NG User Manual
Page 16

Regency
®
L900E Direct Vent Gas Fireplace
16
INST
ALLA
TION
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete 
line of component parts for installation of both 
horizontal and vertical installations. Many items 
are offered in decorative black, as well as gal-
vanized fi nish. 
The minimum components required for a basic 
horizontal termination are:
1 AstroCap
XL
1 90
o
Elbow
1 Rigid
Pipe
Adaptor
1 Wall
Thimble
1 Length of pipe to suit wall thickness
The minimum components required for a basic 
vertical termination are:
1 Vertical
Termination
Cap
1 Rigid
Pipe
Adaptor
 1 Lengths of pipe to adequately
 penetrate 
roof
1 Ceiling
Firestop
 1 Flashing
 1 Storm 
Collar
Wall thickness is measured from the back 
standoffs to the inside mounting surface of 
termination cap. For siding other than vinyl 
furring strips may be used, instead of the vinyl 
siding standoff, to create a level surface to 
mount the vent terminal. The Terminal must 
not be recessed into siding. Measure the wall 
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must 
be used with vinyl siding), measure to outside 
surface of wall without siding and add 2 
inches.
Alternate
Horizontal Termination
Caps
Rigid Pipe
Adapter
(770-994)
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
24”
Pipe
Length
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Vinyl Siding
Standoff (Optional)
Vent Guard - if required*
(Part #946-506/P)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap XL
TM
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent GS and Selkirk Direct-Temp.
AstroCap XL
TM
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary
trademarks of Simpson Dura-Vent Co. Inc.
This product has been evaluated by Intertek for 
using a Rigid Pipe Adaptor in conjunction with 
Duravent Direct-Vent GS and Selkirk Direct-
Temp systems. Use of these systems with 
the Rigid Pipe adaptor is deemed acceptable 
and does not affect the Intertek WHI listing of 
components.
WARNING:
Do not combine venting components from 
different venting systems.
Use of the the AstroCap XL
TM
is acceptable
with all systems.
INSTALLATION
Part # 5DT-ST14 (14")
Part # 5DT-ST36 (36")
IMPORTANT NOTE
• The Simpson Dura-Vent and Selkirk Direct 
 Temp horizontal termination caps cannot 
 be used in any applications.
• Only the AstroCap XL and Snorkels are 
 certifi ed for horizontal terminations.
* A Vent Guard is required when the AstroCap 
is installed above grade at 7 feet or lower.