CAUTION:

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

FAN MAINTENANCE

1) Unplug or disconnect power source to

stove.

2) Remove all logs and the rear log support,

then remove the 6 screws holding the ac-
cess panel in place.

3) Disconnect white wire from fan to power

cord.

4) Disconnect black wire from molex plug to

thermodisc.

5) Unplug wire harness on left rear side panel

(from inside the stove).

6) Disconnect green ground wire from fan

body.

7) Lift fan off of the 2 pins, tip forward and pull

through fi rebox opening.

If your fan requires maintenance or replace-
ment, access to the fan is through the access
panel on the rear wall of the fi rebox. NOTE:
the unit MUST NOT be operated without
the fan access panel securely in place and
correctly sealed.

To remove fan:

IMPORTANT: These fans do collect
a lot of dust from within your home.
Ensure you maintain these fan mo-
tors on a regular basis by vacuum-
ing out the fan squirrel cages.

Replacing fan:

Reverse above steps. Hint for pushing fan down
onto pins
- rub a bit of dish soap on the grommet
so it will slide more easily onto the pin. Check
to make sure the fan is seated properly on the
pins - try to move the fan back and forth, there
should be no noise, if there is check that the
grommets haven't come loose.

Caution: Ensure that the wires do
not touch a hot surface.

IMPORTANT

Disconnect power supply

before servicing

WARNING: Electrical Grounding
Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.

This manual is related to the following products: