INST
ALLA
TION
Discharge Lines
1. Connect quality sanitation hose 1"
(25mm) or 1 1/2" (38mm) I.D. to
discharge fitting on toilet.
2. Run hose to appropriate device (i.e.:
treatment system, holding tank, etc.).
PLUMBING
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline
must have a vented loop installed in the
discharge line. The top of the vented loop
must be a minimum of 4" (10cm) above
the waterline at the boats greatest angle
of heel (see vented loop manufacturer’s
instructions).
Sea Water Models must also have a vented
loop installed between the intake pump
and the toilet bowl.
Double clamp all below waterline
connections.
IMPORTANT
•
Fittings and 90° bends should be kept
to a minimum.
•
In-Line Strainer must be installed on
Sea Water Models per Installation
Instructions. Failure to do so may void
Warranty.
•
Discharging untreated sewage is
forbidden in all U. S. waters within the
three-mile limit.
•
Thru-hull fittings and seacocks must
be installed where they are easily
accessible.
•
Use only quality reinforced hoses.
•
Secure all hoses properly.
Pressurized Freshwater Model
Installed Above Waterline
SeaEra
Toilet
Vacuum
Breaker
Water
Solenoid
Valve
Discharge
Holding Tank
Pressurized Freshwater
Source
Waterline
Shut off
Valve
Sea Water Model with Integral Pump
Installed Below Waterline
SeaEra
Toilet
Waterline
Intake Vented
Loop
Intake
Seacock
Remote
Intake
Pump
In-Line
Strainer
Discharge
Seacock
Discharge
Vented
Loop
Intake
Seacock
Holding Tank
SeaEra Toilet
Y Valve
In-Line
Strainer
Lectra/San
Waterline
Waterline
Waterline
Remote Intake Pump Model
Mounted Above Waterline
Discharge
Seacock
Waterline
Discharge
Vented
Loop
Lectra/San
1 1/2" (38mm)
Discharge Fitting
1" (25mm)
Discharge Fitting
Hose