beautypg.com

Rinnai ENERGYSAVER ES38 User Manual

Page 20

background image

0

Rinnai Corporation ES38 Manual

Drilling Flue Hole

Ensure that there are no gas or water lines, or

electrical circuits in the wall location where the flue

hole is to be drilled.
Drill the flue hole using a 3 1/8 inch (80 mm) drill. A

template is provided. The center of the hole must

be located anywhere within the shaded area, unless

extension kits are used. See the dimensions

diagram.
For weatherboard walls, drill through the center of

the weatherboard from the outside first and then

through the plasterboard.

Flue Hole

3

1/

8"

(8

0

m

m

)

Attach the wall brackets as shown. A template is

provided.

59

3

723

Wall bracket

30

24

Attach Wall Brackets

Attach Back Spacers

Attach side back spacers to both sides of the

appliance with 2 screws each.

FILTER

Flexible Plactic Hose (C)

B

A

FLUE MANIFOLD