beautypg.com

Installation instructions, Warning, Notice – Rinnai ENERGYSAVER ES38 User Manual

Page 14: General instructions

background image

1

Rinnai Corporation ES38 Manual

Installation Instructions

A qualified service technician should install the

appliance and inspect it before use.

If you move, check the gas type in your new area.

The local gas authority will be able to advise on

local regulations.

The installation must conform with local codes or, in

the absence of local codes, with the National Fuel

Gas Code, ANSI Z223.1/NFPA 54, or the Natural

Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home

OEM installation must conform with the

Manufactured Home Construction and Safety

Standard, Title 24 CFR, Part 3280, or, when such a

standard is not applicable, the standard for

Manufactured Home Installations, ANSI/NCSBCS

A225.1, or the standard for Gas Equipped

Recreational Vehicles and Mobile Housing, CSA

Z240.4.

The appliance, when installed, must be electrically

grounded in accordance with local codes or, in the

absence of local codes, with the National Electrical

Code, ANSI/NFPA 70, or the Canadian Electrical

Code, CSA C22.1.

Appliance input ratings are based on sea level

operation and need not be changed for operation up

to 2000 ft (609.9 m) elevation. For operation at

elevations above 2000 ft (609.9 m), refer to the

Conversion Manual.

The appliance and its appliance main gas valve

must be disconnected from the gas supply piping

system during any pressure testing of that system at

test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply

piping system by closing its equipment shutoff valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2

psi (3.5 kPa).

If the flooring is carpet, tile, or other combustible

material other than wood, then the appliance must

be installed on a metal or wood panel extending the

full width and depth of the appliance.

This appliance discharges a large volume of warm

air next to the floor. Any particles in the air such as

cigarette smoke could cause discoloration in nylon

carpets containing dyes or vinyl surfaces.

This appliance is not designed to built in.

This appliance is only for use with the type of gas

indicated on the rating plate. This appliance is not

convertible for use with other gases unless a

certified kit is used. If conversion of the unit is

needed, conversions must be performed by a

qualified service provider at the owner’s expense.

This appliance must not be connected to a chimney

flue serving a separate solid-fuel burning appliance.

Rinnai suggests that a dedicated electrical circuit

with a 120VAC, 60 hz, 10 amp power source be

used.

A test plug are provided for testing of manifold

differential pressure. It is located on the modulating

gas valve.

The appliance should be correctly sized for the

space it is required to heat.

Follow the installations instructions and those in

Care and Maintenance for adequate combustion

and ventilation air.

The flow of combustion and ventilation air shall not

be obstructed.

Clearances to access the appliance during servicing

are 2 inches (50 mm) from the sides, 40 inches (1

m) from the front, and 10 inches (250 mm) from the

top.

General Instructions

WARNING

Do not use substitute materials.
Use only parts certified with the appliance.

If installation is at a location above

2001 ft (610 m), then follow the Adjust

Gas Pressure Settings procedure in

the Conversion Manual.
If installation is at or below 2000 ft

(610 m) then the pressure settings do

not need to be adjusted.

NOTICE