LIGHTING THE WATER HEATER

26

TEST THE WATER HEATER AFTER INSTALLATION

The operation of the water heater must be thoroughly checked by the
installer.

The burner flame must light smoothly and quickly from the pilot flame, and
must go out quietly and completely.

The main burner flame must be stable, although slight lifting at the front
edge of the burner is acceptable when the burner is cold.

The main burner flame should be blue, with a clearly defined inner cone -
luminous yellow or "floating" flames are not acceptable, and must be
corrected by opening the air shutter (refer to

“Air Shutter”

on page 26).

Check the test point pressure and compare with the rating label. The
pressure regulator is not adjustable and if the test point pressure is not
within 5% of the specified value, refer to Rheem or their Accredited Service
Agent.

If unable to get the water heater working properly, contact the nearest
Rheem Service Department or their Accredited Service Agent.

When satisfied everything is working properly instruct the user in the correct
method of operation.


AIR SHUTTER
The air shutter is a hinged flap in the burner aeration tube. It may require
adjustment on installation.

For a Propane and Butane model, the air shutter should be fully open.

For a Town and TLP model, the air shutter should be within 10 mm of the
top of the burner aeration tube.

The shutter is held in place by a screw on the side of the burner aeration
tube.


Note: A Natural gas model does not have an air shutter.