beautypg.com

Dimensions and technical data, Installation – Rheem 300 series User Manual

Page 18

background image

INSTALLATION

18

DIMENSIONS AND TECHNICAL DATA

Model

300 135
620 130

300 170

Storage capacity

litres

135 170

Mass (tank) Empty

kg

54 63

Full

kg

189 233

Dimensions

A B C D E F G H K L M

130 / 135

mm

1615 425 500

988 328 297 1490

58 490 213

75

170

mm

1915 425 500 1213 403 297 1790

58 490 213

75

Gas Details

Hourly Gas

Consumption (MJ)

Min. Gas

Pressure (kPa)

Test Point Gas

Pressure (kPa)

Max. Gas

Pressure (kPa)

130, 135

170

130 to 170 130, 135

170

130 to 170

Natural 30

30

1.13

1.00

1.00

3.50

Propane 30

30

2.75

2.70

2.70

3.50

Butane 25

25

2.75

2.70

2.70

3.50

Town / TLP

29/27

29/27

0.75

0.44

0.44

3.50

Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N, P, B or T is
included in the model number, eg 300135N0, to denote gas type.
Specifications are subject to change with ongoing product improvements.