7 of 59

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.

FIGURE 6: 45° Tilt Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

8

8

50

46

21

21

127

117

BH-60

8

8

59

54

21

21

150

138

BH-80

8

8

65

60

21

21

166

153

BH-100

10

8

73

64

26

21

186

163

BH-115/125

10

8

77

69

26

21

196

176

BH-140/150

12

8

83

74

31

21

211

188

BH-175/200

12

8

85

79

31

21

216

201

FIGURE 7: U-Tube, Standard Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

- UNAPPROVED -

- UNAPPROVED -

BH-60

6

35

62

30

16

89

158

77

BH-80

6

38

68

37

16

97

173

94

BH-100

6

40

75

39

16

102

191

100

BH-115/125

6

46

78

43

16

117

199

110

BH-140/150

6

50

83

47

16

127

211

120

BH-175/200

8

54

87

51

21

138

221

130

B

D

C

A

FIGURE 8: U-Tube, 45°

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

- UNAPPROVED -

- UNAPPROVED -

BH-60

8

8

59

42

21

21

150

107

BH-80

8

8

65

46

21

21

166

117

BH-100

8

8

73

52

21

21

186

133

BH-115/125

8

8

77

61

21

21

196

155

BH-140/150

8

8

83

66

21

21

211

168

BH-175/200

8

8

85

70

21

21

216

178

C

D

B

A