Regency Freestanding Woodstove

4

HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

FLOOR

PROTECTION*

F1100S WITH

AIRMATE SHIELD

LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION

MODEL: REGENCY SMALL FREESTANDING STOVE - F1100S
TESTED TO:

CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6621 (MAY 1993)

F1100S WITHOUT
AIRMATE SHIELD

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND
OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG
BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR
USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

FRONT

BACK

L

K

M

SI

DE

SIDE

K

405 mm / 16 in

L

150 mm / 6 in

M 150 mm / 6 in

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100 .
IN USA:

LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA

VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-
FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

CERTIFIED TO COMPLY WITH JULY 1990,

PARTICULATE EMISSION STANDARDS.

UNITED STATES ENVIRONMENTAL

PROTECTION AGENCY

FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT
COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE
ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR
GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO
THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

F1100S WITH AIRMATE SHIELD

F1100S WITHOUT AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

SIDEWALL

A 380 mm /15 in D 685 mm / 27 in

BACKWALL

B 265 mm / 10.5in E 430 mm / 17 in

CORNER

C 280 mm / 11 in F 585 mm / 23 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 330 mm / 13 in

D 635 mm / 25 in

BACKWALL

B 125 mm / 5 in

E 290 mm / 11.5in

CORNER

C 230 mm / 9 in

F 535 mm / 21 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

A 345 mm / 13.5in D 650 mm / 25.5in

BACKWALL

B 125 mm / 5

in E 290 mm / 11.5in

CORNER

C 125 mm / 5

in F 430 mm / 17 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - ALCOVE

SIDEWALL

A 330 mm / 13 in

D 635 mm / 25 in

BACKWALL

B 280 mm / 11 in

E 445 mm / 17.5in

CORNER

C 205 mm / 8 in

F 510 mm / 20 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 280 mm / 11 in

D 585 mm / 23 in

BACKWALL

B 150 mm / 6 in

E 320 mm / 12.5in

CORNER

C 150 mm / 6 in

F 460 mm / 18 in

SIDEWALL

A 230 mm / 9 in

D 535 mm / 21 in

BACKWALL

B 125 mm / 5 in

E 290 mm / 11.5in

CORNER

C 75

mm / 3 in

F 380 mm / 15 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

G 280 mm / 11 in

I 585 mm / 23 in

BACKWALL

H 180 mm / 7 in

J 345 mm / 13.5in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - ALCOVE

SIDEWALL

G 330 mm / 13 in

I 635 mm / 25 in

BACKWALL

H 125 mm / 5 in

J 290 mm / 11.5in

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

MADE IN CANADA

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEPT

OCT

NOV

DEC

A

D

BACKWALL

SIDEW

A

LL

B

E

G

G

I

BACKWALL

SIDEW

A

LL

SIDEW

A

LL

H

J

F

ADJACENT WALL

SIDEW

A

LL

C

CAUTION

DA

TE OF MANUF

ACTURE

2001

2003

2002

WD

908-281 01/03

MANUFACTURED BY:

FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4

100

100

* In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.

This is a copy of the label that accompanies
each Regency Small Freestanding Woodstove
(F1100S). It is located in the upper right corner

of the back of the stove. We have printed a copy
of the contents here for your review.

SAFETY LABEL

NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.