Installation, Gravity air feed kit option – Regency WARMHEARTH Z2510L User Manual

Page 14

background image

Regency Z2510 WarmHearth

14

INSTALLATION

GRAVITY AIR FEED KIT OPTION

The Gravity Air Feed Kit is designed to extend the heat output vent above the WarmHearth or to the
front or the side. The upper louver opening is blocked off and fl ex duct is connected to the vent holes
in the top of the unit and run to vent grills installed above the unit or to the
side. Both 8" diameter insulated Flex pipes must be used along with the
air vent to bring additional air into the chase.

OPTION 2

External Blower with Thermo-Disc

The thermodisc allows the fi replace to warm up
properly before the blower will switch on. The
blower is also switched off if the fi replace tem-
perature falls below suitable heating levels.

OPTION 3

Internal and External Blowers

with a Thermodisc

When both blowers are used the thermodisc
should be connected to the external blower.

Note: There are two holes provided for attach-

Parts List

Qty.
1

Block-off plate 6-1/2" x 26"

4 Connector

collars

4 Adjustable

clamps

2

Upper air vent frame

2

5' lengths of fl exible vent pipe (8" dia.)

2

Large upper vent covers

1

Small lower vent cover

1

Lower air vent frame

2

Insulation sleeves for fl exible vent pipe

1) Remove the screws from both of the vent hole

covers (Vent cover A) on top of the unit.

2) Take the connector collar and rotate it in the

hole to cut through 4" of insulation. Remove
the insulation from pipe.

3) Remove the screws on the lower cover (Vent

cover B) and slide it back under the insula-
tion.

4) Slide the connector collar into the fl ex duct and

secure with an adjustable clamp.

FAN PART NUMBERS

The parts listed below are available from
Regency. Please see your Regency Dealer
for prices.

000-912 Internal

Blower

Assembly:

Includes 150 CFM, 2 speed blower,
Blower Switch Kit and Thermo-Disc
Kit.

000-928

Blower Switch Kit:
Includes switch box, two way
switch and a three way switch.

ing the thermodisc to the fi replace. The
holes are on the right hand side just
below the ashlip.

(Fastens to louvers)

000-918 One-way

Damper:

Eight inch diameter butterfl y valve
necessary for external blower
installation.

The remainder of the components discussed
here are optional and are available from your
Regency dealer or local heating supply outlet.
Below is the listed specifi cations required for
these parts:

External Blower: 8 inch diameter inlet a mini-

mum capacity of 433 CFM
at a static pressure of 0.75
in. w.c. and is listed in the
country where the blower is
to be used.

Wall Switch:

1 speed blower requires

2-way

switch

2 speed blower requires

3-way switch etc.

Wall Thermostat: For both wall switch and

thermostat see your Regency
dealer or heating supplier for
compatible parts.