4.5 Precautions When Opening and Closing IC Socket

When opening and closing the IC socket, hold the adapter horizontally as shown in Figure 4.4.
Otherwise the inside of the IC socket may become damaged and cause an electrical insulation failure.

Figure 4.4 Holding the adapter in a horizontal position

4.6 Precautions When Handling Adapter

Do not directly touch the connector in the IC socket and the pins on the PROM programmer connector
because dirt may cause an electrical insulation failure.

When not using this product, attach the connector pins of this product to the conductive sponge as
it was shipped from the factory.

4.7 Setting Programming Area

When writing and erasing programs, be sure to set the programming area. And also, specify its device
of the PROM programmer.

Table 4.1 Programming area

Side view

MCU

Internal flash

memory

area of MCU

M5M28F101

ROM size

Programming area

Device

PROM programmer

M38B79FFFP

1000

16

- FFFF

16

01000

16

- 0FFFF

16

60KB