4.5 Precautions When Opening and Closing IC Socket
When opening and closing the IC socket, hold the adapter horizontally as shown in Figure 4.4.
Otherwise the inside of the IC socket may become damaged and cause an electrical insulation failure.
Figure 4.4 Holding the adapter in a horizontal position
4.6 Precautions When Handling Adapter
Do not directly touch the connector in the IC socket and the pins on the PROM programmer connector
because dirt may cause an electrical insulation failure.
When not using this product, attach the connector pins of this product to the conductive sponge as
it was shipped from the factory.
4.7 Setting Programming Area
When writing and erasing programs, be sure to set the programming area. And also, specify its device
of the PROM programmer.
Table 4.1 Programming area
Side view
MCU
Internal flash
memory
area of MCU
M5M28F101
ROM size
Programming area
Device
PROM programmer
M38B79FFFP
1000
16
- FFFF
16
01000
16
- 0FFFF
16
60KB