REMOTE CONTROLLERS INSTALLATION

1) Determine a suitable location for the

controller.

2) Make three holes in the wall as shown.

3) Run the cable between the controller and

the Rinnai Water Heater or the controller
and the other controller.

4) Remove the face plate from the remote controller, using a screw driver.

5) Connect the cable to the remote controller.

6) Mount the controller to the wall using the holes drilled in step 2.

7) Disconnect the power from the Rinnai Water Heater.

8) Remove the cover of the Rinnai Water Heater.

9) Remove the plastic cover from the PCB and electrical connections.

10) Thread the cable through the

access hole at the base of the

unit and connect the wires to the

controller terminals on the right

hand side bottom of the PCB.

11) Secure the controller cable using

the clamp provided.

12) Replace plastic cover over PCB and

then replace the cover of the Rinnai

Water Heater.

DO NOT ATTEMPT TO CONNECT THE REMOTE CONTROLLERS WITH THE
POWER ON; THERE IS 120 VOLT POTENTIAL, NEXT TO THE REMOTE
CONTROLLER CONNECTIONS INSIDE THE UNIT. DO NOT CONNECT THE
REMOTE CONTROLLER TO THE 120VAC TERMINALS PROVIDED FOR THE
OPTIONAL SOLENOID DRAIN VALVES.
All service and wiring should be
performed by a registered installer.

securing screw

wiring hole

securing screw

Outline of Remote

1-21/32˝

3-5/16˝

U273-430(00).indd 47

06.2.8 10:37:10 AM