beautypg.com

Easy connect (ezconnect™) instructions – Rinnai V3237FFU User Manual

Page 38

background image

38

Rinnai Corporation

V3237 Models

Easy Connect (EZConnect™) INSTRUCTIONS

(REU-EZC-1US)

EZConnect Installation

1. EZConnect allows the installation of two Water Heater units together utilizing the EZConnect

cord.

2. Install the two Water Heater units 2" ~ 18" apart so that the cord will be able to reach between

two units.

3. Do not install more than 18" apart between two water heaters. To do so, will cause temperature

fluctuations (cold water sandwich effect) whereby the water is shut off, then turned on again.

4. The EZConnect shall be disabled before installing with the MSA controller system.

Recommended Installation Layout:

5. Before installing the EZConnect cord, remove the protective cap from the 3 pin connector

marked “EZConnect” located in the wiring harness of the Primary Unit. (Fig.1)

6. To install the EZConnect cord, plug in the cord on both the

Sub unit and Primary unit accordingly – see installation layout
above. (Fig.2,3)

7. Securely tighten the EZConnect cord to the bottom of Water

Heater by using Cable Clamp and Screw supplied. (Fig.4)

(Both of Primary and Sub Unit)

• Temperature settings can only be changed on the primary unit controller.
• This system can not use the bathfill function.

Sub Unit

Primary Unit

2~18”

PCB

To PCB

To EZConnect

EZConnect

Plug in

EZConnect

Remove this

protective

Cap

PCB

Fig.1

Fig.2

Fig.3

Tighten the EZConnect cord

EZConnect Cable

Cable Clamp(Supplied)

Screw(Supplied)

Fig.4

U273-430(00).indd 38

06.2.8 10:37:06 AM