GAS PRESSURE SETTING


11.Remove rubber access plug and adjust the

regulator screw on the modulating valve (fig. 4
and 4a) as required to the pressure below.







12.Lock the regulating screw on the modulating

valve.


13.Set the appliance to 'Forced High' combustion

by setting both no. 2 and no. 3 dipswitches of
the bottom set of switches (SW2) to 'ON'.
(fig.5) Ensure maximum water flow.


14.Check the burner test point pressure.

15.Adjust the high pressure potentiometer on the

Printed Circuit Board below SW2 (fig. 6) to the
pressure shown below. The potentiometer is
very sensitive, turn no more than a few de-
grees at a time; then let the pressure settle
down before turning it more.







16.IMPORTANT: Set dip switch no. 2 and no. 3

on the bottom set of switches (SW2) to 'OFF'
to return the appliance to 'Normal' combustion.
(fig. 7)


17.Close hot water tap.

18.Turn OFF the gas supply and 230V power

supply.


19.Remove pressure gauge, and replace sealing

screw.


20.Turn 'ON' the gas supply and 230V power

supply.


21.Operate unit and check for gas leaks at test

point.


22. Replace the front cover of the appliance.

N.G

0.8 mbar

Propane 1.7 mbar

N.G

9.0 mbar

Propane

22.6 mbar