beautypg.com

Temperature controls - information – Rinnai 24e User Manual

Page 25

background image

25

TEMPERATURE CONTROLS - INFORMATION

Do not push the On/Off button on the
Master controller after transferring priority
of temperature selection to a Secondary
controller as the system will shut down.





Do Not Turn OFF
the Master
Controller

Temperature priority can not be switched
to another controller when the water is
flowing through the water heater.

If a temperature higher than 50ºC has
been selected on the Master controller
and priority of temperature selection is
transferred to another controller (or it is
turned off), then back again (or turned on
again), the temperature on the Master
controller will automatically drop to 50ºC.
If the set point is less than 50

0

C it will not

alter. This is a safety feature.







Master Another Master
Controller Controller Controller

Do not clean the remote control with
solvents or detergents. Use only a soft
damp cloth.

Depending on the weather conditions
and the length of the pipe between the
heater and the tap in use, there may be a
variation between the temperature dis-
played at the controller and the tempera-
ture at the tap.

If a temperature higher than 42

0

C has

been selected on the Universal control-

ler and priority of temperature selection is
transferred to another controller (or con-
troller is turned OFF), then back again (or
turned ON again), the temperature will
automatically drop to 42

0

C. If the set

point is less than 42

0

C it will not alter.

This is a safety feature.






Universal Another Universal
Controller Controller Controller

48

0

C

50

0

C

Controller 1
in use

Controller 2
cannot take

priority