beautypg.com

Technical details – Rinnai 24e User Manual

Page 10

background image

10

TECHNICAL DETAILS













































* Factory Setting

**Minimum operation flow based on temperature setpoint and inlet conditions.

Infinity Model

Infinity 24e Units

Installation External

Nat Gas Press Low

0.8

mbar

Nat Gas Press High

9.0

mbar

LPG Press Low

1.7

mbar

LPG Press High

22.6

mbar

Height 600

mm

Width 350

mm

Depth 170

mm

Weight 18

kg

Flue System

Forced Exhaust

Temp. Range Controllers

37 - 75

deg C

Temp. Range without
Controllers

37,40,43,50,

55*,65,75

deg C

Ignition

Direct Electronic
Ignition

Gas Consumption Low

Nat Gas

5.8

kW

LPG 5.8

kW

Gas consumption High

Nat Gas

52

kW

LPG 52

kW

Max Flow raised 33C

18

L/min

Min Operation Flow

2.7**

L/min

Water Pressure Nom.

1.4 - 10

bar

Power Supply

230 V / 50 Hz

Elec. Consumption Standby
(with 1 remote connected)

6 Watts

Elec. Consumption Run

55

Watts

Elec. Consumption
Anti-frost Heaters On

100 Watts