beautypg.com

Electrical – RIDGID R5010 User Manual

Page 7

background image

6

7

DOUBLE INSULATION

Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-wire
grounded power cord. All exposed metal parts are isolated
from the internal metal motor components with protect-
ing insulation. Double insulated tools do not need to be
grounded.

WARNING:

The double insulated system is intended to protect
the user from shock resulting from a break in the
tool’s internal wiring. Observe all normal safety
precautions to avoid electrical shock.

Servicing of a tool with double insulation requires extreme
care and knowledge of the system and should be performed
only by a qualified service technician. For service, we sug-
gest you return the tool to your nearest authorized service
center for repair. Always use original factory replacement
parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor.

It should be

connected to a power supply that is 120 volts, 60 Hz, AC
only (normal household current).
Do not operate this tool
on direct current (DC). A substantial voltage drop will cause
a loss of power and the motor will overheat. If your tool does
not operate when plugged into an outlet, double-check the
power supply.

EXTENSION CORDS

When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the tool will draw. An un-
dersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter’s Laboratories
(UL) should be used.

When working outdoors with a tool, use an extension cord
that is designed for outside use. This type of cord is desig-
nated with “WA” on the cord’s jacket.
Before using any extension cord, inspect it for loose or ex-
posed wires and cut or worn insulation.

**Ampere rating (on tool faceplate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0

Cord Length Wire Size (A.W.G.)

25' 16 16 16 16 14 14

50' 16 16 16 14 14 12

100' 16 16 14 12 10 —

**Used on 12 gauge - 20 amp circuit.

WARNING:

Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on
lumber, tools or other obstructions while you are
working with a power tool. Failure to do so can result
in serious personal injury.

WARNING:

Check extension cords before each use. If damaged
replace immediately. Never use tool with a damaged
cord since touching the damaged area could cause
electrical shock resulting in serious injury.

ELECTRICAL