U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

7

INSTALLATION

EXTERIOR VENT TERMINAL LOCATIONS

.

B

B

B

B

A

C

V

V

V

V

V

V

V

A

A

V

Fixed

Fixed

Openable

Closed

Closed

Openable

N

L

B

E

B

M

D

F

K

H

j

V

ertical

T

ermination

V

V

ent

terminal

Area

where

terminal

is

not

permited

A

Air

supply

outlet

24"

V

A

G

Inside

corner

det

ail

V

24"

18"

V

ertical

T

ermination

A

=

Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

B

=

Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

C

=

Clearance to permanently closed window *(min. 12"/30cm)

D

=

Vertical clearance to ventilated soffit located above the terminal within a horizontal

distance of (24"/60cm) from the centerline of the terminal (min. 22"/55cm) check with

local code.

E

=

Clearance to unventilated soffit (min. 12"/30cm)

F

=

Clearance to outside corner (12"/30cm)

G

=

Clearance to inside corner (12"/30cm)

H

=

Not to be installed above a meter/regulator assembly within

(3'/90cm) horizontally from the centerline of the regulator.

J=

Clearance to service regulator vent outlet *(min. 36"/90cm)

K

=

Clearance to non-mechanical air supply inlet to building

or the combustion air inlet to any other appliance *(12"/30cm) #(9"/23cm)

L

=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

#3' (91cm) above if within 10' (3m) horizontally.

M

=

**Clearance above paved sidewalk or a paved driveway located

on public property *(min. 84"/2.1m)

N

=

Clearance under veranda, porch, deck, or balcony *(min.

12"/30cm)***

Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings a

nd serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

# In accordance with the current ANSI Z223.1/NFPA 54, National Gas Code