U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater

This is a copy of the label that accompanies
each ULTIMATE Rear Vent Direct Vent Free-
standing Gas Stove. We have printed a copy of

SAFETY LABEL

the contents here for your review. The safety
label is located on the inside of the drop down
pedestal door.

NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.

Copy of Safety Label for U37

DOOR SEAL ADJUSTMENT:

Please check that door is properly sealed.

Periodic adjustment of latch may be required.

FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA

A 7-1/2" /190 m m
B 3"

/76 m m

E 4-1/2" /114 m m

Min. Ceiling

Height from top

of unit / Min.

Plafond Hauteur

en haut de

l'appareil:

36" / 914 mm

Minimum

Clearances to

Combustibles/

Degagement

Minimum Des

Materiaux

Combustibles

Serial No./No de serie

VENTING: Only for direct discharge without duct connection. This appliance must be installed in
accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the
current ANSI Z223.1 in the USA or the current CAN/CGA-B149 in Canada. For Manufactured Home
Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's
installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280,
or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and
Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

Model/Modele:

U37-NG

Listed: GRAVITY DIRECT VENT WALL FURNACE
Certified for/Certifiée pour: CANADA AND U.S.A.

Tested to:

CGA 2-17-M91, ANSI Z21.88b-2003/CSA 2.33b-2003

REPORT NO. 476-1846-00 (Oct. 2000)
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

FACTORY EQUIPPED FOR NATURAL GAS: Model U37-NG
Min. supply pressure

5.0"

WC/C.E. (1.24Kpa)

Manifold pressure High 3.8"

WC/C.E. (0.947Kpa)

Manifold pressure Low 1.1"

WC/C.E. (0.27Kpa)

Orifice size

#37

DMS

Altitude

0-4500 ft/pi

(0-1370m)

Maximum Input

30,000 Btu/h

(8.79Kw/h)

Minimum Input

15,000 Btu/h

(4.39Kw/h)

ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:
Pression d’alimentation minimum
Pression à la tubulure d’échappement élevée
Pression à la tubulure d’échappement élevée
Dimensions de l’orifice
L’altitude
Débit calorifique maximum selon
Débit calorifique minimum selon

918-028a

Model/Modele:

U37-LP

221

FACTORY EQUIPPED FOR PROPANE: Model U37-LP
Min. supply pressure

12"

WC/C.E. (3.00Kpa)

Manifold pressure High 11"

WC/C.E. (2.74Kpa)

Manifold pressure Low 2.9"

WC/C.E. (0.72Kpa)

Orifice size

#52

DMS

Altitude

0-4500 ft/pi

(0-1370m)

Maximum Input

30,000 Btu/h

(8.79Kw/h)

Minimum Input

15,000 Btu/h

(4.39Kw/h)

Pression d’alimentation minimum
Pression à la tubulure d’échappement élevée
Pression à la tubulure d’échappement élevée
Dimensions de l’orifice
L’altitude
Débit calorifique maximum selon
Débit calorifique minimum selon

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.