VA Series Indoor LS Manual

Temperature Controller Installation

1. Determine a suitable location for the

controller.

2. Make three holes in the wall as shown.

3. Run the cable between the controller and the

Rinnai water heater or the controller and the
other controller.

4. Remove the face plate from the temperature

controller using a screwdriver.

5. Connect the cable to the temperature

controller.

6. Mount the controller to the wall using the

holes drilled in step 2.

7. Disconnect the power from the Rinnai water

heater.

8. Remove the cover of the Rinnai water heater.

9. Remove the plastic cover from the PCB and

electrical connections.

10. Thread the cable through the access hole at

the base of the unit and connect the wires to
the controller terminals on the right hand side
bottom of the PCB.

11. Secure the controller cable using the clamp

provided.

12. Replace plastic cover over PCB and then

replace the cover of the Rinnai water heater.

Do not attempt to connect the temperature controllers
with the power on. There is 120 volt potential, next to
the temperature controller connections inside the unit.

Do not connect the temperature controller to the
120VAC terminals provided for the optional
solenoid drain valves.

All service and wiring should be performed by a
registered installer.

WARNING

Outline of Remote

securing screw

1-21/32"

3-5/16"

securing screw

wiring hole

CABLE CLAMP

REMOTE

CONTROL CABLE

REMOTE CONTROL

CONNECTION TERMINALS

Mounting the Controller

Follow the procedure below to install MC-91 or
MCC-91 temperature controllers.