Trouble shooting for common issues, Water quality, Accessing operating information – Rinnai R50LSI User Manual
Page 15
VA Series Indoor LS Manual
15
Trouble Shooting for Common Issues
I don’t have any hot water when I open the tap.
Make sure there is gas, water, and electricity to the
Rinnai water heater (power is turned on and the gas is
turned on).
When I was using the hot water, the water got cold.
If you adjusted the flow from the tap to lessen it, you
may have gone below the minimum flow required. The
Rinnai water heater requires a minimum flow rate to
operate. (See the specification page for the flow rate
of your model.) Decrease the temperature setting at
the temperature controller or increase the water flow.
White smoke comes out of the exhaust.
During colder weather when the exhaust temperature
is much hotter than the outside air, the exhaust fumes
condense producing water vapor.
When I open a hot tap, I do not immediately get hot
water.
Hot water must travel through your plumbing from the
Rinnai water heater to the faucet. The time period for
hot water to reach your fixture is determined by the
amount of water in the plumbing system between the
water heater and the fixture, water pressure, and the
flow rate of the fixture.
After I turn off the hot water tap, the fan on the
Rinnai water heater continues to run.
The fan is designed to continue running for a short time
after the flow of water stops. This is to ensure constant
water temperatures during rapid starting and stopping,
as well as exhausting any residual gas flue products
from the unit.
Consideration of care for your water heater should
include evaluation of water quality. If the water quality
exceeds the target levels provided in the table, you
may want to treat or condition the water.
* Source: Part 143 National Secondary Drinking Water
Regulations
Maximum Level
Total Hardness
Up to 200 mg / L
Aluminum *
Up to 0.2 mg / L
Chlorides *
Up to 250 mg / L
Copper *
Up to 1.0 mg / L
Iron *
Up to 0.3 mg / L
Manganese *
Up to 0.05 mg / L
pH *
6.5 to 8.5
TDS (Total Dissolved
Solids) *
Up to 500 mg / L
Zinc *
Up to 5 mg / L
Water Quality
Accessing
Operating
Information
To display the most recent error codes press and hold the “On/Off” button for 2 seconds. While holding the “On/
Off” button press the ▲ button. The last 9 error codes will flash one after the other. To exit this mode press the
“On/Off” and ▲ button as before.
To display the water flow through the water heater press and hold the ▲ button for 2 seconds and without
releasing the ▲ button press the “On/Off” button.
To display the outlet water temperature press and hold the ▼ button for 2 seconds and without releasing the ▼
button press the “On/Off” button.