beautypg.com

Specifications – Rinnai R50LSI User Manual

Page 3

background image

VA Series Indoor LS Manual

3

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

Model

R50LSi

R75LSi

R94LSi

R98LSi

R98LSi-

ASME

Minimum Gas Consumption Btu/h

15,000

19,000

Maximum Gas Consumption Btu/h

150,000

180,000

237,000

Hot water capacity (Min - Max) *

0.6 - 5.0 GPM

(2.3 - 18.9 L/min)

0.6 - 7.5 GPM

(2.3 - 28.4 L/min)

0.6 - 9.4 GPM

(2.3 - 35.5 L/min)

0.6 - 9.8 GPM

(2.3 - 37 L/min)

Hot water capacity (45°F rise)

5.0 GPM

(18.9 L/min)

6.7 GPM

(25.4 L/min)

8.5 GPM

(32.2 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Temperature Controller Default Setting

104º F (40º C)

Maximum Temp Setting (commercial **)

160º F (71º C)

185º F (85º C)

Maximum Temp Setting (residential)
see Temperature Ranges for more information

140º F (60º C)

Minimum Temperature Setting

98º F (37º C)

Weight

50 lb (23 kg)

55 lb (25 kg)

Efficiency Rating

Noise level

49 dB

Electrical
Consumption

Normal

79 W

99 W

Standby

2 W

Anti-frost Protection

100 W

116 W

By-Pass Control

Fixed

Electronic

Minimum Gas Supply
Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum Gas Supply
Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

Direct Electronic Ignition

Electric Connections

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

Water Supply Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

Maximum Water Supply Pressure

150 PSI

Remote Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

84.0%

199,000 Natural

Gas

190,000 Propane

7.1 GPM

(27.0 L/min)

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** for commercial and hydronic applications requiring higher temperatures

This manual is related to the following products: