19

Section 5 Verifying Operation

1. When using the E6000 emulator for the H8S/2168 group, turn on the emulator according to the

procedures described in the H8S/2168 Group E6000 Emulator User's Manual
(HS2168EPI61HE).

2. Verify the user system interface cable connections by accessing the external memory and ports

to check the bus states of the pins with the MEMORY_FILL command (emulator command). If
an error is detected, recheck the soldered IC socket and the location of pin 1.

3. The emulator connected to this user system interface cable supports two kinds of clock sources

as the MCU clock: an emulator internal clock and an external clock on the user system. For
details, refer to the emulator user’s manual (HS2168EPI61HE).
⎯ To use the emulator internal clock

Select the clock in the emulator station as the system clock (

φ), by using the CLOCK

command (emulator command).

⎯ To use the external clock on the user system

Select the target clock by using the CLOCK command (emulator command) and supply the
external clock from the user system to the emulator. When a crystal oscillator to the EXTAL
and XTAL terminals for the system clock (

φ) the crystal oscillator will oscillate in the circuit

as shown in figure 13. External clock must be input from the EXTAL terminal. The clock
input conditions are same as those for the H8S/2168 group in the hardware manual.

To E6000 emulator

R2 270

R1 1 M

HCU04

HCU04

HCU04

EXTAL

XTAL

Figure 13 Oscillator Circuit