TROUBLESHOOTING

Air leak near the top of the tool or
in the trigger area

PROBLEM

POSSIBLE CAUSE

SOLUTION

Loose screws
Worn or damaged O-rings or
seals

Tool does nothing or operates
sluggishly

Tool jams frequently

Tighten screws
Install Overhaul Kit

Inadequate air supply
Inadequate lubrication
Worn or damaged O-rings or bumper

Tighten screws
Install Overhaul Kit

Verify adequate air supply
Lubricate tool
Install Overhaul Kit

Air leak near the bottom of the
tool

Loose screws
Worn or damaged O-rings or bumper

Incorrect fasteners
Damaged fasteners
Loose magazine
Dirty magazine
Worn or damaged driver

Verify that fasteners are the correct size
Replace fasteners
Tighten screws
Clean magazine
Install Driver Maintenance Kit