ERROR( Unknown Command )
Fail response, if NITZ network service is not supported
and
OUTPUT PULSE OFF
The X refers to output pin number,
X=1,2,3,4,5,6,7,8,9,all.
The Y refers to either ON or OFF
Command syntax for
for example, Output_Pulse 1 On 5m30s
Value ranges for
If Network Indication and Time Zone (NITZ) network service is
supported, the range is from 1 second to 7 days.
If NITZ network service is not supported, the range is from 1 second to 23
hours 59 minutes and 59 seconds.
If NITZ network service is supported, the range is from 1 … 7
days.
1…23
Value examples for valid
7d, 6d23h59m59s, 45m, 59s, 4h25s, 30m45s
, etc.
Value examples for invalid
7d1s
Maximum time (7 days) exceeded
3m3m
There cannot be two unit fields of the same
100s
Maximum second and minute value is 59. Use 1m40s instead
24h
Maximum hour value is 23. Use 1d instead of 24h
9.3.8
Cancelling Output Pulses
It is possible to cancel pulses before the
40/49