Table 12. Output_Pulse X commands
Command Type
Command
Comments
Output_Pulse X On
term123 Output_Pulse X
On
Response:
OUTPUT_PULSE X ON
Response, when pulse time expires:
OUTPUT X: Y
The X refers to output pin number, X=
1,2,3,4,5,6,7,8,9,all.
The Y refers to either ON or OFF.
Response, if another pulse command has already been
issued:
OUTPUT_PULSE X ON
OUTPUT X LOCKED
Fail response, if invalid
ERROR( Unknown Command )
Fail response, if NITZ network service is not supported
and
OUTPUT_PULSE ON
The command sets to
output pin X on for a
requested time interval,
that is, pulse
Output_Pulse X Off
term123 Output_Pulse X
Off
Response:
OUTPUT_PULSE X OFF
Response, when pulse time expires:
OUTPUT X:Y
Response, if another pulse command has already been
issued:
OUTPUT_PULSE X OFF
OUTPUT X LOCKED
Fail response, if invalid
The command sets to
output pin X off for a
requested time interval,
that is, pulse
39/49