Nokia 12 GSM MODULE REMOTE I/O User Manual
Page 35
Table 7. The Input_Get X commands
Command Type
Command
Comments
Input_Get All
term123 Input_Get All
Response:
INPUT_GET ALL: OK
INPUT1: Y
INPUT2: Y
INPUT3: Y
INPUT4: Y
INPUT5: Y
INPUT6: Y
INPUT7: Y
INPUT8: Y
INPUT9: Y
INPUT10: Y
INPUT11: Y
The Y varies according to the input pin state and it can be:
xxxx mV if the input analog (pins 1-3), xxxx = value
between 0-2800
ON or OFF if the input is digital (pins 4 -11)
The command
reads all inputs
and the response
returns the value
and state
Input_Get X
term123 Input_Get X
Response:
INPUT_GET X: OK
INPUT X: Y
The X refers to input pin number,
X=1,2,3,4,5,6,7,8,9,10,11.
The Y varies according to the input pin state and it can be:
xxxx mV if the input is analog (pins 1-3), xxxx = value
between 0-2800
ON or OFF if the input is digital (pins 4-11)
The command
reads input pin X
and the response
returns the value
or state of it
according to
queried input pin
31/49