To operate this hi-efficiency fireplace as a basic system, the

blower is not required, however, to enhance its efficiency a
blower is recommended.

A blower kit (NZ62)

may be purchased

with the op-

tion of adding up to one additional blower. These blowers
are installed in the bottom of the unit and are used to direct

the heat into the room where the fireplace is located. The
blowers are controlled, by a variable speed switch, located

inside the fireplace.

A thermostAtic Air coNtrol (NZ690kt)

may be

used for constant heat,

complete with automatic damper and

thermostat, wall mounted in the room containing the fireplace,
and at least

10 feet (minimum) from the fireplace.

A hot Air grAvity veNt system (NZ220)

may be

used to distribute heat to an adjoining room (located either

above, or beside the room containing the fireplace) by way
of vents, eliminating the need of an additional blower. While
this system may be used in conjunction with the optional

blowers, it could reduce the flow of hot air being distributed
to additional rooms. It must be experimented with and the
dampers adjusted manually to suit your requirements. This
may take a few attempts; thereafter adjustments should no
longer be required as is normally experienced with your
central heating system registers.
The heat shield cover plate must be removed before

installing the gravity vent. The hot air vent must be in-

stalled in an upward direction! NEVER install in a down-

ward direction

. Figure 6. Th

e hot air gravity vent system

is not to be connected to a central heating system (for

this application use the NZ62CH). This option may not

be used in mobile homes.
No more than

two hot air gravity vents can be installed to

fireplace. Individual vent runs are not to exceed 10 feet.

All hot air gravity vents must be insulated.

A ceNtrAl heAtiNg system (NZ62ch)

may be

used to heat rooms up to 50 feet from the unit. A wall mounted
thermostat located in the room to be heated controls the

blower supplying warm air from the room containing the fire-
place. If a hot air duct system exists, the central heat blower
may safely be tied into this system to reduce the amount of
new ducting required. Consult with a heating specialist to
ensure a proper duct layout for your home. If the NZ62CH
is installed at the bottom of the unit, it could introduce a cool

draft into the room that the fireplace is installed in.

A hot Air distributioN kit (gA-566)

may be used

to distribute warm air from the fireplace base (only) into a
separate location in the home.

These options may be incorporated with one another. If the
optional blowers are to be installed, make provision during

framing to route a 110 volt power line to the fireplace. Detailed
installation instructions are included with each venting kit.

figure 6

hI-EFFICIENCY hEATING

FIVE OPTIONS

STOVE TOP

figure 4

HEAT SHIELD COVER PLATE

figure 5b

figure 5

When attached to the top or sides of the unit, it provides a
higher heat output.

This option may not be used in

mobile homes.

REMOTE VIEWING OPTIONS

NOTE: MASONRY REMOTE VENTING OPTIONS COME OFF THE

SIDE INSTEAD OF THE TOP.

NO

DUCTING

CENTRAL HEATING

OPTION

GRAVITY VENT

OPTION (1 DUCT)

CENTRAL HEATING &

GRAVITY VENT OPTION

GRAVITY VENT

OPTION (2 DUCT)