1. Move the fireplace into position. Try to centre the exhaust

flue of the fireplace, midpoint between two joists to prevent
having to cut them. use a plumb bob to line up the centre.
2. Cut and frame an opening in the ceiling to provide a
minimum clearance of 2" between the outside of the chimney
and any combustible material. dO NOT FIll ThIS SpACE
WITh ANY TYpE OF mATERIAl!
Nail headers between
the joists for extra support. Firestop spacers must be placed

on the bottom of each framed opening in any floor or ceiling
that the chimney passes through.
3. Hold a plumb bob from the underside of the roof to deter-
mine where the opening in the roof should be. Cut and frame
the roof opening maintaining proper 2" clearances.

figure 14

OFFSET ChIMNEY INSTALLATION

ADDING ChIMNEY SECTIONS

figure 13 - 4 elbows

figure 12 - 2 elbows

figure 11 - straight up

No Off-Set. Minimum overall chimney
height is 11 feet.

Single off-set with two 15°, 0° or 45°
elbows. Minimum overall chimney
height is 11 feet.

Double off-set with four 15°, 0° or
45° elbows. Minimum overall chimney
height is 11 feet.

* The first flue offset closest to the top of the unit must

be a minimum distance of 12 inches from the top of the

fireplace.

NOTE: 30° or 45° offsets may be installed back to back.

figure 15

Add chimney sections, twist locking (clockwise) securely, to
the required height. use a rafter radiation shield whenever
the chimney system is enclosed within an attic area.

The first flue offset closest to the top of the unit
must be a minimum distance of 12" from the top
of the fireplace.
An insulated elbow must be used when it becomes neces-
sary to offset the chimney in order to clear a joist or to pass
through an upstairs closet.

Attach an elbow to the chimney section, angled toward the
offset. Secure with - #8X1/2" sheet metal screws. To achieve
the minimum offset, attach and secure a return elbow to the

first. To achieve longer offsets, you may install any available
length of chimney pipe between the elbows.
Supports must be used on the first vertical chimnney section
after a return elbow.

figure 16