beautypg.com

NuTone 761WHNT User Manual

Read and save these instructions, Decorative ventilation fan with light, Typical installations

background image

Page

MODEL 761WHNT

DECORATIVE VENTILATION

fAN WITH LIgHT

READ AND SAVE THESE INSTRUCTIONS

TYPICAL INSTALLATIONS

HOUSING

MOUNTING TABS

POWER CABLE

GRILLE

PAN

GLASS

LIGHT SHADE

CEILING

JOIST

CEILING

MATERIAL

HOUSING

HOUSINg MOUNTED

DIRECTLY TO jOIST

2x6 (or larger)

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING

TABS

POWER CABLE

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

CEILING

MATERIAL

GRILLE

PAN

GLASS

LIGHT SHADE

HOUSINg MOUNTED

TO 2x4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING

MOUNTING

TABS

POWER CABLE

ADDITIONAL

FRAMING

"

I

"

JOIST

"

I

"

JOIST

GRILLE

PAN

GLASS LIGHT SHADE

CEILING

MATERIAL

HOUSINg MOUNTED TO “I” jOIST

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

*

Additional framing must be a 2x6 (minimum height), at least 9-inches long.

*

*

WARNINg

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR

INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address

or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock the service disconnecting means to prevent

power from being switched on accidentally. When the service

disconnecting means cannot be locked, securely fasten

a prominent warning device, such as a tag, to the service

panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and

standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment

manufacturer’s guideline and safety standards such as those

published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a tub or

shower.

8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.

CAUTION

!

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. This product is designed for installation in FLAT CEILINGS

ONLY. Do not mount this product in a wall.

3. The light fixture assembly must be mounted to the fan housing

assembly included with this product. Do not mount the light

fixture assembly to a wiring outlet box.

4. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power

unit.

5. Please read specification label on product for further informa-

tion and requirements.

Installer:

Leave this manual with the

homeowner.
Homeowner:

Use and Care information on page 4.

PLAN THE INSTALLATION

The unit will operate

most quietly and

efficiently when

located where the

shortest possible

duct run and

minimum number

of elbows will be

needed.
Use a roof cap or

wall cap that has a

built-in damper to

reduce backdrafts.
Plan to supply the

unit with proper

line voltage and

appropriate power

cable.

4-in. ROUnD

ELBOW(S)

*

4-in.

ROUnD

DUCT

*

WALL CAP

*

*

Purchase

separately

inSULATiOn

(Can be placed

around and over

fan housing.)

fAn

hOUSing

SUSPENDED CEILINgS

Housing hung with wires -

3-point mount.

MOUNTING

TAB

GRILLE

PAN

SUSPENDED

CEILING

MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOUSING

GLASS

LIGHT SHADE