beautypg.com

Napoleon Fireplaces GVFL18N User Manual

Page 9

background image

W415-0530 / 12.14.05

9

When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed.
1. STOP! Read the above safety information on this la-

bel.

2. Set the thermostat to lowest setting.
3. Turn off all electric power to the fireplace.
4. Open the control door. Turn the gas knob clockwise

to off.

5. Wait five (5) minutes to clear out any gas. If you smell

gas including near the floor, STOP! Follow "B" in the
above safety information on this label. If you don't smell
gas go to the next step.

6. Find pilot located in front of the back log.

A. This fireplace is equipped with a pilot which must be lit

by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for

gas and next to the floor because some gas is heavier
than air and will settle on the floor.

C. Use only your hand to push in and turn the gas control

knob. Never use tools. If the knob will not push in and
turn by hand, do not try to repair it. Call a qualified serv-
ice technician. Force or attempted repair may result in a
fire or explosion.

D. Do not use this fireplace if any part has been under water.

Immediately call a qualified service technician to inspect
the fireplace and replace any part of the control system
and any gas control which has been under water.

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone

in your building.

• Immediately call your gas supplier from a neighbour's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire depart-

ment.

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

gas knob

oxygen depletion sensor

P

I

NO

L

O

T

FF

O

7. Turn gas knob counter-clockwise

to pilot.

8. Depress and hold gas knob while lighting the pilot

with the push button igniter. Keep knob fully depressed
for one minute, then release. If pilot does not continue
to burn repeat steps 3 through 7.

9. With pilot lit, turn gas knob counter-clockwise

to

on. When the pilot has been turned off, ignition of the
main burner may be delayed from 1-2 minutes.
When the pilot has been left burning, ignition of the main
burner should occur almost immediatley.

10. If equipped with remote on-off switch, main burner may

not come on when you turn the valve to on. Remote
switch must be in the on position to ignite burner.

11. Turn on all electric power to the fireplace.
1. Turn off all electric power to the fireplace if service is to

be performed.

2. Push in gas control knob slightly and turn clock-

OT

PIL

LO

IH

T

P

I

L

O

N O

FF O

GAS KNOB AT OFF

FOR YOUR SAFETY READ BEFORE LIGHTING:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

WHAT TO DO IF YOU SMELL GAS: