beautypg.com

Operation / maintenance, Match lighting instructions, Lighting instructions operating instructions – Napoleon Fireplaces GVFL18N User Manual

Page 8

background image

W415-0530 / 12.14.05

8

If heater shuts off, do not relight until you provide
fresh air. If heater keeps shutting off, have it serv-
iced. Keep burner and control compartment clean.
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condition
caused by the curing of the logs and the "burn-off" of inter-
nal paints and lubricants used in the manufacturing proc-
ess and will not occur again. Open a window to ventilate
the room during this burn off period.

After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles burning off. In both cases, open a window to suffi-
ciently ventilate the room.
Purge the gas line with the glass door open. Assure that
a continuous gas flow is at the burner before closing
the door.

CORRECT PILOT

FLAME

INCORRECT PILOT

FLAME

figures 32

MATCH LIGHTING INSTRUCTIONS

1. Remove any items necessary for easy access to the

pilot (for example: logs, screens, etc.).

2. Follow appropriate lighting instructions found previously.

Instead of pushing and releasing the piezo button, light
a match and hold the flame to the end of the pilot and
ignite the pilot.

3. After control knob has been released and pilot stays lit,

reinstall any items that were removed for pilot access.

4. Call a qualified service technician for repair or replace-

ment of the piezo ignitor.

LIGHTING INSTRUCTIONS

OPERATING INSTRUCTIONS

IF

THE

FIREPLACE

IS

EQUIPPED

WITH

DECORATIVE

GLASS

DOORS

,

THEY

MUST

BE

FULLY

OPENED

WHEN

OPERATING

THIS

GAS

LOG

SET

.

2

OXYGEN DEPLETION SENSOR PILOT

CLEANING

This procedure must be performed by a qualified

service person!

Inspect the pilot for any visible contamination or debris (usu-
ally lint, pet hair, spider webs, carpet fibre, etc.) and remove.
Disconnect the pilot from the pilot tubing line. Using a

7

/

16

wrench, remove the injector from the pilot housing. Blow out
the housing in the same direction as the gas flow.
Re-install the injector and the pilot tube, turn on the gas and
check for leaks.
If this does not improve the performance, replace the pilot
with an exact replacement. The device is tamper resistant
with no field serviceable parts.

1. Locate the pilot burner at the rear of the log set on the
right side.
2. Turn the gas control knob to the pilot setting (on the left
side of the appliance closest to the back).
3. With the control knob depressed, push the piezo igniter
continuously until the pilot lights.
Hold the control knob in for 1 minute and release.
If the pilot goes out, repeat steps 2 and 3.
4. Once the pilot stays burning, make certain that the on / off
switch is in the off position. Turn the control knob counter-
clockwise to the on position.
5. Turn the on / off switch to the on position to ignite the
burner.

OPERATION / MAINTENANCE

3

1

4

5

This manual is related to the following products: