beautypg.com

Install grille & bulbs, Connect wiring install grille & bulbs, Page model qtxn110hflt 8. plug-in light – NuTone QTXN110HFLT User Manual

Page 3: Attach grille, Install bulbs, Attach light lens, Connect electrical wiring, Remove light lens from grille, Finish ceiling, Caution

background image

Page

MODEL QTXN110HFLT

8. Plug-in

light.

Hold grille as-

sembly up near

housing. Connect

light plug from

grille assembly to

receptacle inside

of housing.

INSTALL GRILLE & BULBS

9. Attach

grille.

Remove the (2)

grille mounting
screws
from

the sides of the

housing. (See

Step 8 illustra-

tion.) Use these

screws to attach

the grille to

the housing as

shown.

To avoid damage to the grille: DO NOT OVERTIGHTEN

SCREWS. Tighten screws only until grille is snug against

ceiling material.

10. Install

bulbs.

The unit

accepts (2)

18-Watt 3500K

(maximum)

GU24 based

fluorescent

bulbs and (1)

7-Watt night

light bulb.

11. Attach

light lens.

Hook the tabs

on one end of

the lens into the

slot in the grille.

Lift other end

of lens up and

snap into place.

GRILLE MOUNTING

SCREWS

5. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use

proper UL approved connectors to secure house wiring to

wiring plate. Connect wires as shown in wiring diagram(s).

CONNECT WIRING

INSTALL GRILLE & BULBS

7. Remove

light lens
from grille.

Insert a small

flat-bladed screw-

driver into the slot

at one end of the

light lens. Care-

fully pry the lens

out.

6. Finish ceiling.

Install ceiling material. Cut out ceiling material closely

around housing.

GREEN

WHITE

to

WHITE

HEAT (2-position rocker)

LIGHT (red)

NIGHT LIGHT (blue)

(3-position rocker)

4-FUNCTION CONTROL

GROUND

120 VAC LINE IN

BLACK to BLUE

BLACK to RED

BLACK to BLACKS

FAN (2-position rocker)

RED

WIRING PLATE

FROM VENTILATOR

VENTILATOR

HOUSING

LIGHT

&

FAN

HEAT

&

NIGHT LIGHT

BLACK to BLUE

(Light)

WHITE to WHITE with red stripe

RED to RED

(Fan)

RED to BLACK

(Heat)

BLACK to YELLOW

(Night Light)

WHITE to WHITE

RED

CAUTION

RATING SPECIFICATIONS

• The three-position

rocker switch is rated 5 A

@ 125VAC. Use this switch

for Lights ONLY.

• Each two-position rocker

switch is rated 15 A @ 120VAC. Use these switches for Heat and Vent.

• The total load on this control must not exceed 20 A @ 120VAC.