Model maxtop, Performance, Dimensions maxtop – Lifebreath 200MAX RX EN User Manual
Page 11: Engineering data

11
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams.
It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. 120 VAC, 1.4 Amps.
FILTERS - Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV - Four threaded inserts at corners of case designed to
accept four reinforced polyester straps that are supplied with the unit.
DEFROST
Recirculating damper defrost system.
DEHUMIDISTAT
Adjustable Internal Dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation. Drain connections 2 - 1/2"
(12 mm) OD.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode, Recirculation mode
(on compatible units), (each mode has 5 speeds). Control pad can be removed
from HRV and remotely mounted.
Weight 87 lbs. (39.5 kg) Shipping Weight 89 lbs. (40.5 kg)
PERFORMANCE
HVI CERTIFIED
Net supply airflow in cfm (L/s) against external static pressure
E.S.P
cfm
L/s
@ 0.1” (25 Pa)
196
(93)
@ 0.2” (50 Pa)
188
(89)
@ 0.3” (75 Pa)
178
(84)
@ 0.4” (100 Pa)
165
(78)
@ 0.5” (125 Pa)
149
(71)
Maximum Temperature Recovery
80%
Sensible Effectiveness
@ 117 cfm (55 L/s )
(CSA C439M)
72%
Sensible Efficiency
@ 117 cfm (55 L/s)
32
O
F (0°C)
64%
Sensible Efficiency
@ 67 cfm (31 L/s)
-13
O
F (-25°C)
70%
VAC @ 60HZ
120
WATTS / Low speed
74
WATTS / High speed
164
Amp rating
1.4
TOP VIEW
SIDE VIEW
25 1/2 "
(648 mm)
26 1/2"
(673 mm)
22 1/2"
(572 mm)
FRONT VIEW
ALL DUCT CONNECTIONS
ARE 6" (150 mm)
18"
(457 mm)
7 1/2"
(191 mm)
SUPPLY OF
FRESH AIR
FRESH AIR
SUPPLY
TO BUILDING
STALE AIR
RETURN FROM
BUILDING
STALE AIR
EXHAUST
DRAIN
CONNECTION
CONTROLS
*Service Clearance
25" (635 mm)
OPTIONS
99-104
Digital Electronic Timer - 20/40/60 min.
99-109
Air Sentry™ Air Quality Monitor designed to accept
remotely mounted Control Pad
99-250
Ventilation Dehumidistat - Dehumidistat designed to
accept remotely mounted Control Pad
99-163
Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 6”
(150mm)
99-164
Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 6”
(150mm)
99-186
Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) mesh
screen
WARRANTY
Units carry a LIFETIME warranty on the heat recovery core and a 5
year replacement parts warranty.
TI-100-NE
0904
MAXTOP FANCURVE
200
150
175
75
50
100
125
25
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
Air Flo
w (cfm)
Static Pressure (inH
2
0)
HIGH SPEED
*
MEDIUM HIGH SPEED
MEDIUM SPEED
MEDIUM LOW SPEED
LOW SPEED
4
5
3
2
1
4
3
2
1
5
*
Manufacturers Data
Model MAXTOP
All units conform to
CSA and UL standards.
DIMENSIONS MAXTOP
inches (mm
)