- 6 -

1. SELECT BLOWER OPTION AND INSTALL DUCTWORK

Either an interior or exterior blower or in-line blower may be used with this hood. The NuTone Premier 60000 Series must
be installed with blower models RM325H, RM326H, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only.
Other blowers cannot be substituted. (Blowers sold separately).
NOTE: In addition to the blower models listed above, this hood is also compatible with older internal versions 325H

and 326H. However, discard the installation instructions included with those blowers and contact our technical
support to obtain replacement instruction.

Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 6, 9, 10, 11,
13 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use 2” duct tape to
seal duct joints.

7" (178 mm)

ROUND DUCT

ROOF CAP

7" (178 mm)

ROUND
ELBOW

24" TO 30" (609 to 762 mm)

ABOVE COOKING SURFACE

WALL CAP

HOOD

DECORATIVE

FLUE

or SOFFIT

12"

(305 mm)

HH0024A

MODEL RM325H SINGLE BLOWER

TYPICAL DUCTWORK

10" (254 mm)

ROUND DUCT

ROOF CAP

WALL CAP

HOOD

DECORATIVE

FLUE

or SOFFIT

4-1/2" x 18-1/2"

to 10"

(114 x 470 to

254 mm) ROUND

TRANSITION

(see page 4)

HH0025A

12"

(305 mm)

24" TO 30" (609 to 762 mm)

ABOVE COOKING SURFACE

MODEL RM326H DUAL BLOWER

TYPICAL DUCTWORK

EXTERIOR BLOWER

EXTERIOR

BLOWER

HOOD

DECORATIVE

FLUE

or SOFFIT

HH0026A

12"

(305 mm)

24" TO 30" (609 to 762 mm)

ABOVE COOKING SURFACE

332KR

ROUGH-IN KIT

(see page 5)

10" (254 mm)

ROUND DUCT

10" (254 mm)

ROUND ELBOW

MODEL 331H, 332H, 335 OR 336

EXTERIOR BLOWER TYPICAL DUCTWORK

In-line blower

10” round duct

HH0066A

24” minimum
above cooking
surface

Roof cap

Wall
cap

Hood

MODEL HLB3, HLB6, HLB9 OR HLB11

IN-LINE BLOWER TYPICAL DUCTWORK