Freedom F-64 Installation Instructions
L
NAPCO Security Systems
WI1501A 9/06
Page 20
lay or the "Pre-Alarm Warning", then no report will be sent and no messages will be displayed at the keypad/Touchpad. If the area is 
disarmed during the Abort-Delay, then an "Alarm Canceled' will be displayed at the keypad/Touchpad and no report will be sent. If the 
area is disarmed during or within the Cancel Window Duration, then an "Attempting to Cancel" will be followed by an "Alarm Canceled" 
for a successful cancellation. Otherwise, the report had been sent and will be responded appropriately to by the Central Station. Cancel 
must be provided with a Central Station Telephone Number, proper Subscriber O/C Report ID Numbers and a valid Cancel Code to 
Telco 3. A Cancel Window ("Report Cancel Window") is the duration that the system will attempt to cancel a report, after the report is 
sent. 
 
Cancel Next Test Timer Report on Any Report See Test Timer 
 
Central Station Receiver Data Format See Data Format 
 
Chime; Chime Duration 
This annunciator feature may be used on any zone to sound a tone at the Touchpad while disarmed when the zone goes into trouble. 
Access the ACTIVATE CHIME function to enable or disable the Chime Mode. This feature is programmable by zone and "Chime 
Timeout Duration". A time must be programmed for the chime to function. Note: "0" means no chime value is programmed. 
 
Chime Zone 2 
CHIME2 adds an additional tone onto the regular "Chime Zone" tone. It allows some zones to have distinctive annunciator chimes to 
identify the door or zone. "Chime Zone" must be selected on any Touchpad for all area keypad/Touchpads to chime. While the 
standard chime zone sounds a steady tone when a chime zone is faulted, Chime 2 will sound a pulsating tone when a Chime 2 zone is 
faulted. This can be used to help the customer easily identify the door which has been opened. Program the zone as Chime 2 in the 
Zone Features screen. This feature is programmable by zone and "Chime Timeout Duration". 
 
Chirp Output on Keyfob Arm/Disarm 
If enabled, when arming with a keyfob, the PGM2 output chirps. 
 
Clear Program 
Caution: Erases the dealer program. Use this feature to start a new customized default program. Access the correct address location 
(see the Programming Instructions WI1502), then press the 
U
button.
 
Closing Report; Closing Report Only on Conditional Closing; Conditional Closing; Include Selective/Group Bypass In 
Conditional Closing/Status; Status Report; Disable Closing Report 
On arming, the communicator can transmit a unique Closing Code for each user and a status report that identifies the problem zone to 
the central station. Note that Subscriber Identification Numbers and a Closing Code and/or conditional closing code must be entered for 
any closing report. 
•
Select which users will report closings for each telephone number, even if "Closing Report Only on Conditional Closing" is selected. 
Normally, a closing report will consist of the Closing Code and the number of the user that armed. If the user armed with an auto-
bypassed zone (or selective/group bypassed zone if "Include Selective/Group Bypass In Conditional Closing/Status" was 
programmed), the Conditional Closing Code will also be sent. 
•
Select "Closing Report Only on Conditional Closing" to report only when arming with an auto-bypassed zone (and selective-
bypassed zone if "Include Selective in Conditional Closing/Status" is programmed). 
•
Select "Status Report" to send a closing followed by a status report that identifies the problem zone(s). A typical Status Report is 
represented by the following example. 
Example (4/2 Format): A burglar breaks into a commercial establishment during the night, breaking the window foil on Zone 5. The 
Open/Close Subscriber Identification Number is "1234"; the Alarm Code for Zone 5 is "3,5" (Burglary Zone 5); the Subscriber 
Identification Number is "6789"; the Closing Code is "C". The communicator will send the following report to the central station. 
When alarm occurs: 
"6789 35" – Alarm, Zone 5 
Closing Report: 
"1234 C1" – Closing, User 1 (User 1 returned, inspected damage & rearmed; the same transmission would occur for 
User 11, 21, 31, etc.)
"1234 F5" – Trouble, Zone 5 (zone status at time of closing: Window foil still broken; Zone 5 auto-bypasses, repair
required; the same transmission would occur for Zone 15, 25, 35, etc.).
 
Cold Start 
Caution: Erases the entire program (codes, schedules, etc.), and loads the following defaults: 8 hardwire zones (Zones 1-8) are pro-
grammed in Area 1, with no other zone features enabled and no alarms generated. In addition, a Default User 1 Code of "123" is en-
abled as an Arming Code in Area 1, and after powering up, the installer is required to enter Program Mode using the Dealer Program 
Glo
ssar
y