DESCRIPTION

DESCRIPTION

The capacity of the MA3000, GEM-Series and Signature

5500 and SS-P Series control panels may be expanded

through the use of GEM-EZM zone expansion modules.

GEM-EZM4 modules provide up to four additional zones;

GEM-EZM8 modules, up to 8 additional zones. Four-zone

and 8-zone modules may be combined as necessary to

supply the required number of zones. Refer to the installa-

tion instructions for the control panel in use for wiring

requirements for UL-listed applications.

WIRING

WIRING

Wire the expansion zones to the module and the module

to the control panel in accordance with the wiring diagrams

using wire no thinner than #22AWG. Install end-of-line

resistors on all zones even if one or more zones are not

used.

Note:

Note: The addition of Zone Expansion Modules will re-

duce the amount of current available at the control panel’s

Auxiliary Power Output terminals.

MODULE ASSIGNMENT

MODULE ASSIGNMENT

Regardless of how the modules are arranged, the expan-

sion zones are divided into consecutively-numbered

groups of four. Each 4-zone module comprises one group

of zones; each 8-zone module comprises two groups.

Every module must be assigned a unique ‘‘base address’’.

In the case of a 4-zone module, the base address number

is the same as its group number. For the 8-zone module,

the base address number will be the lower of its two group

numbers. Note that (a) groups must be numbered con-

secutively (that is, missing numbers are not permitted); and

(b) no two modules may be numbered alike.

Example. Two GEM-EZM8s and one GEM-EZM4 are used

to provide 20 expansion zones:

Groups 1 & 2

Group 3

Groups 4 & 5

GEM-EZM8

GEM-EZM8

GEM-EZM4

GEM-EZM4

GEM-EZM8

GEM-EZM8

Base Addr ‘‘1’’

Base Addr ‘‘3’’

Base Addr ‘‘4’’

The base address is assigned to the module by proper

selection of Address Jumpers JP1-JP5 (to the right of the

LED) in accordance with Table 1. Also refer to the Zone

Wiring Diagram.

Base

Base

Address

Address

Address Jumpers

Address Jumpers

JP5

JP5

JP4

JP4

JP3

JP3

JP2

JP2

JP1

JP1

1

ON

ON

ON

ON

OFF

2

ON

ON

ON

OFF

ON

3

ON

ON

ON

OFF

OFF

4

ON

ON

OFF

ON

ON

5

ON

ON

OFF

ON

OFF

6

ON

ON

OFF

OFF

ON

7

ON

ON

OFF

OFF

OFF

8

ON

OFF

ON

ON

ON

9

ON

OFF

ON

ON

OFF

10

ON

OFF

ON

OFF

ON

11

ON

OFF

ON

OFF

OFF

12

ON

OFF

OFF

ON

ON

13

ON

OFF

OFF

ON

OFF

14

ON

OFF

OFF

OFF

ON

15

ON

OFF

OFF

OFF

OFF

16

OFF

ON

ON

ON

ON

17

OFF

ON

ON

ON

OFF

18

OFF

ON

ON

OFF

ON

19

OFF

ON

ON

OFF

OFF

20

OFF

ON

OFF

ON

ON

21

OFF

ON

OFF

ON

OFF

22

OFF

ON

OFF

OFF

ON

Table 1. Jumper emplacement as a function of Base Address.

Table 1. Jumper emplacement as a function of Base Address.

Shaded area is not applicable to GEM-P3200 or SS-P3200.

Shaded area is not applicable to GEM-P3200 or SS-P3200.

PROGRAMMING

PROGRAMMING

The control panel must be programmed with regard to

the modules (4-zone or 8-zone) in use. Referring to the

respective Programming Workbook, program EZM TYPE to

enable the module. Starting in the first location and pro-

ceeding in succession, program a ‘‘1’’ for each 4-zone

group of expansion zones in the system. For example, if

one GEM-EZM8 is used for Zones 9 through 16 (two groups

of 4), program a ‘‘1’’ in the first and second locations (right

‘‘nibble’’). Similarly, if an GEM-EZM4 is used for Zones 17

through 20 (1 group), program a ‘‘1’’ in the third location

(right ‘‘nibble’’). Thus, each GEM-EZM4 will require a ‘‘1’’ in

only one location whereas each GEM-EZM8 will require a

GEM-EZM4, GEM-EZM8

GEM-EZM4, GEM-EZM8

ZONE EXPANSION MODULES

ZONE EXPANSION MODULES

for MA3000, GEM-Series,

for MA3000, GEM-Series,

Signature S5500 & SS-P Series

Signature S5500 & SS-P Series

Control Panels

Control Panels

NAPCO SECURITY SYSTEMS, INC.

333 BAYVIEW AVENUE

AMITYVILLE, NEW YORK 11701

SALES, REPAIRS & TECHNICAL SERVICE

TOLL FREE: (800) 645-9445

TECHNICAL SERVICE DIRECT LINE

TOLL FREE: (800) 645-9440

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

© Napco 1997

WI583C 2/97

This manual is related to the following products: