beautypg.com

Mode 1 output timing – National Instruments PC-DIO-96 User Manual

Page 34

background image

Configuration and Installation

Chapter 2

PC-DIO-96 User Manual

2-16

© National Instruments Corporation

Mode 1 Output Timing

The following figure illustrates the timing specifications for an output transfer in mode 1.

T2

T3

WR*

OBF*

INTR

DATA

T4

T6

T5

ACK*

T1

Name

Description

Minimum

Maximum

T1

WR* = 0 to INTR = 0

250

T2

WR* = 1 to output

200

T3

WR* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* pulse width

100

T6

ACK* = 1 to INTR = 1

150

All timing values are in nanoseconds.