WARNING

CLEARANCES TO COMBUSTIBLES

MINIMUM CLEARANCES TO
COMBUSTIBLES:
-

18” to top

-

1” to sides

-

8” to bottom

-

0” to rear

Do NOT use the appliance if any part has been
under water. Call a qualifi ed service technician
IMMEDIATELY to have the appliance inspected
for damage to the electrical circuit.

IT IS NECESSARY TO HARD WIRE THIS

APPLIANCE.

This appliance must be electrically connected and
grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1
CANADIAN ELECTRICAL CODE in Canada or the
ANSI/NFPA 70-1996 NATIONAL ELECTRICAL
CODE in the United States.

ELECTRICAL CONNECTION

HARD WIRING CONNECTION

FIGURE 3

1 2

3 4

YELLOW

BROWN

W

H

I

T

E

B

L

A

C

K

IGNITOR
WIRE

IGNITOR

GAS

VALVE

SWITCH

CONTROL MODULE

110v

POWER

SUPPLY

GFI

(Ground Fault Interrupter)

G

R

O

U

N

D

Illustration for reference only.

Follow the complete installation

instructions included with the GFI.

RE

SET

TES

T

RISK OF ELECTRIC SHOCK!

Control and valve operate with 110v.

24”

MAX.

18”

MIN.

OUTDOOR

8”

MIN.

VENTILLATED

SOFFIT

!

WARNING

The GSST8 is designed for outdoor application
only. The unit must be installed in the cabinet
provided. The cabinet is designed to be installed
on fi nished surfaces.

The GSST8 can be recessed into a structure a
maximum of 12” provided that all clearances
are maintained.

The GSST8 cabinet may be installed directly
onto a combustible surface.

FIGURE 4

NOTE: During assembly, anti-oxidant
compound was applied to all electrical
connections. If replacing the existing wire
harness or disconnecting any connectors, it is
highly recommended to re-apply anti-oxidant
compound to the relative connections.

COMBUSTION AND VENTILLATION

AIR

This fi replace is intended for installation on an outdoor patio
or in your yard. It must never be installed inside the warm
air envelope of your structure.
It is highly recommended that this fi replaces be installed in a
“sheltered” area. Direct wind will cause an erratic fl ame and
possible pilot or main burner outage.
An erratic fl ame could also lead to excessive carboning
(black soot), this condition is not a safety issue but is visually
undesirable.
Typical installation may include covered patio, screened
porch, gazebo, or on an outside wall of a house.

NOTE: Ensure the area has adequate ventilation.