beautypg.com

Installation, 49 gas line access electrical access – Napoleon Fireplaces GSST8N User Manual

Page 5

background image

5

W415-0689 / 06.25.08

FIGURES 1a-c

DIMENSIONS

Note: All gas connections must be contained within the

appliance when complete.

1. The appliance is designed to accept a 1/2” gas supply line. The
appliance is equipped with a 1/2” manual shut-off valve.

2. The access to the gas inlet is located in the bottom of the
cabinet.

3. The shut off valve / fl ex connector assembly must always be
contained within the cabinet.

4. When fl exing any gas line, support the gas valve so that the
lines are not kinked.

5. Check for gas leaks by brushing on a soap and water
solution.

GAS INSTALLATION

11

/

16

49

GAS LINE

ACCESS

ELECTRICAL

ACCESS

3

/

8

36

1

/

2

1

9

/

16

7

15

13

W385-0380

SHUT OFF

VALVE

FLEX
CONNECTOR

INSTALLATION