beautypg.com

Norton Abrasives C6136 User Manual

Page 43

background image

43

7. For warranty and service information on Monarch Hydraulic pumps, contact

Monarch Hydraulics at:
Phone: 616-458-1306
Web Site:

http://www.monarchhyd.com/

The Norton Company does not warranty the Hydraulic Pump. If any
warranty or service of the Hydraulic Pump is required contact your nearest
Monarch Hydraulics service center @ (616) 458-1306, or from the Internet:

http://www.monarchhyd.com/


8. Monarch Hydraulic Pump Symptom /Cause

Symptom Cause

Motor Fails To Start

Motor Start Solenoid Switch
Electrical Switch "Open" Circuit Motor

Load Fails To Hold

Check Valve-Main (Poppet Type)
D.R. Lowering Valve (two-way, Two Position)
Manual Override

Load Drops Slow

D.R. Lowering Valve (two-way, Two Position)
System Filter

Motor Runs But Load Fails To Raise

D.R. Lowering Valve (two-way, Two Position)
Manual Override
"Ground Fault'
Relief Valve
Suction Filter
Pump Losing Prime (Low Or No Oil In Pump)
Cylinder - Piston Type
Worn Pump

Motor Runs Slow And Sluggish

Low Voltage
Motor
Relief Valve

Load Fails To Lower

D.R. Lowering Valve (two-way, Two Position)
System Filter
Electrical Switch
"Open" Circuit

9. Monarch Hydraulic Pump Test Equipment

a. Pressure Group:

A small 0 5000 PSI pressure gauge, preferably glycerin filled, is a
very valuable and relatively inexpensive tool for checking pressure in
the various sections of the circuit.

b. DC Test Light:

A test light is simply a light bulb which has one end connected by a
wire to an alligator clip and the other end connected to a metal probe.
It is used to check the electrical circuit when the battery is connected
to the system. The alligator clip is grounded and the light glows when

This manual is related to the following products: