Norton Abrasives C6136 User Manual
Page 43
43
7. For warranty and service information on Monarch Hydraulic pumps, contact
Monarch Hydraulics at:
Phone: 616-458-1306
Web Site:
http://www.monarchhyd.com/
The Norton Company does not warranty the Hydraulic Pump. If any
warranty or service of the Hydraulic Pump is required contact your nearest
Monarch Hydraulics service center @ (616) 458-1306, or from the Internet:
http://www.monarchhyd.com/
8. Monarch Hydraulic Pump Symptom /Cause
Symptom Cause
Motor Fails To Start
Motor Start Solenoid Switch
Electrical Switch "Open" Circuit Motor
Load Fails To Hold
Check Valve-Main (Poppet Type)
D.R. Lowering Valve (two-way, Two Position)
Manual Override
Load Drops Slow
D.R. Lowering Valve (two-way, Two Position)
System Filter
Motor Runs But Load Fails To Raise
D.R. Lowering Valve (two-way, Two Position)
Manual Override
"Ground Fault'
Relief Valve
Suction Filter
Pump Losing Prime (Low Or No Oil In Pump)
Cylinder - Piston Type
Worn Pump
Motor Runs Slow And Sluggish
Low Voltage
Motor
Relief Valve
Load Fails To Lower
D.R. Lowering Valve (two-way, Two Position)
System Filter
Electrical Switch
"Open" Circuit
9. Monarch Hydraulic Pump Test Equipment
a. Pressure Group:
A small 0 5000 PSI pressure gauge, preferably glycerin filled, is a
very valuable and relatively inexpensive tool for checking pressure in
the various sections of the circuit.
b. DC Test Light:
A test light is simply a light bulb which has one end connected by a
wire to an alligator clip and the other end connected to a metal probe.
It is used to check the electrical circuit when the battery is connected
to the system. The alligator clip is grounded and the light glows when