13. — Trouble-shooting

• the motor will not start

- a fuse may have blown and needs replacing.

- the cable or the wall socket may be defective and

needs checking.

• the suction power is reduced

- the dust bag may be full and needs replacing,

- the filter may be clogged and needs shaking,

- The by pass valve is open

The by pass valve protects the motors against an

overheating that may occur when there is not enough

cooling air.

You should not release this mechanism unnecessarily

by closing the suction inlet with your hand while the

machine is working.

When the hose or the tube is blocked or the filter

needs to be cleaned, the airflow is interrupted or not

longer sufficient and the by pass valve opens. It is not

necessary to shut down the system while removing the

blockage.

Having done that, you may continue with your work.

• the vacuum cleaner stops

- the thermal cut-out has switched off the motor as a

result of an obstruction of the hose, wand or nozzle.

Remove the cause of the obstruction.

- when the motor is cool, it will automatically start

again.

Specifications

Rated power W

DUST CLASS

FREQUENCY (Hz)

GROUNDED

Protection grade (moist., dust) –

Airflow without hose l/sec – m3/h

Vacuum kPa - hPA

VACUUM MAX (KPA) – (HPA)

Suction power with hose W

Sound pressure level at 1.5 m Lpa – dB(A) (ISO 3744)

MAIN FILTER TYPE

Main filter area cm2

Exhaust filter, ULPA, surface area U15 cm2

Container capacity l

Dust bag capacity l

INLET (MM)

LENGTH X WIDTH X HEIGHT (CM)

Weight kg

Specifications and details are subject to change without prior notice.

IVT1000 CR

EU - UK

220-240V

1200

M

50-60

X

IP40

38 - 1368

19,8 - 198

19,8 - 198

250

61

GORETEX PTFE

2100

2573

12,5

6,5

32

Ø30 x 62,5

7,75

IVT1000 CR H

EU –UK

220-240V

1200

H

50-60

X

IP40

35 - 1260

20 - 200

20 - 200

236

61

HEPA H13

2573

2573

12,5

8

32

Ø30 x 72,5

9,2

IVT1000 CR

Safe Pack

EU – UK

220-240V

1200

H

50-60

X

IP40

35 - 1260

20 - 200

20 - 200

236

61

HEPA H13

2573

2573

-

6,5

32

Ø30 X 70

8,2

IVT1000 CR

US

110-120V

1100

M

50-60

X

IP40

36 - 1296

19,6 - 196

19,6 - 196

240

61
GORETEX PTFE

2100

2573

12,5

6,5

32

Ø30 x 62,5

7,75

IVT1000 CR H

US

110-120V

1100

H

50-60

X

IP40

34 - 1224

19,8 - 198

19,8 - 198

232

61

HEPA H13

2573

2573

12,5

8

32

Ø30 x 72,5

9,2

IVT1000 CR

Safe Pack

US

110-120V

1100

H

50-60

X

IP40

34 - 1224

19,8 - 198

19,8 - 198

232

61

HEPA H13

2573

2573

-

6,5

32

Ø30 X 70

8,2

This manual is related to the following products: