NCR S26 User Manual
Page 137

Sample RAID Configuration
NCR S26 Hot Plug Server User Guide
C-19
Adaptec AIC-7880 Ultra/Ultra Wide BIOS v1.22S2
<
(Refer to the Adaptec SCSI documentation for additional information
about these settings).
2. Select SCSI Disk Utilities. Observe that the 2 GB disk drive and the CD-
ROM drive are displayed with the correct information. If a low-level
format on the 2 GB disk drive is needed, perform it now. It is usually not
needed.
3. Select Configure/View Host Adapter Settings and set the parameters as
follows:
SCSI Bus Interface Definitions
Host Adapter SCSI ID
[7]
SCSI Parity Checking
[Enabled]
Host Adapter SCSI Term
[Low ON/High ON]
Boot Device Options:
Boot Target ID
[0]
Boot LUN Number
[0]
4. Select SCSI Device Configuration and set the parameters as follows:
SCSI Device ID (tab to desired device)
Initiate Sync Negotiation
[yes]
Maximum Sync Transfer Rate*
[40]
Enable Disconnection
[yes]
Initiate Wide Negotiation
[yes]
Send Start Unit Command
[yes]
*Note: See note in step 6.
5. Press Esc to return to previous menu.