beautypg.com

Mtr select (meter select), Input, Mtr select (meter select) input – New Media Technology Omnia ONE Multicast User Manual

Page 41

background image

Mtr Select (Meter Select)


Selects whether the Input levels or Output levels are displayed on the front panel L & R LED bargraph meters.
Please note that in the initial release software the meters when set to monitor Output levels will only monitor the
analog outputs.

Input

There are nine controls under the heading “Input” and each will be explained in the order in which they appear
in the menu:

<-Exit

Click on this option to return to the Input/Output submenu.

Input Src (Input Source)

Allows the selection of Analog or AES/EBU (digital) as the primary input source to the
OmniaONE.

Fover Time (Failover Time)

Failover Time is a feature that when set to a value other than zero (disabled) allows the
OmniaONE to automatically select another input source if the currently selected one fails.
Failover Time is the amount of time that will elapse after the failure of audio before the unit
makes the decision to switch to another input. For instance, if Failover Time is set for seven
seconds and the primary audio source fails, seven seconds later the unit will switch to the
secondary audio input. If, at any time, audio is restored on the primary input (for 1 second,
continuously), the unit will switch back to the primary audio input. It will remain with the
primary input unless another failure is detected.

Fover Src (Failover Source)


Failover Source selects which audio input: Analog or AES/EBU digital will serve as the secondary

audio input. Note that the audio input that is selected under Input Source (above) will always be

the Primary audio input. A source selected under Failover Source will always be the secondary

source.

Anlg Level (Analog Level)

Adjusts the master audio input level for the analog inputs which are derived from the rear panel
XLR female input connectors. (See

Proper Setting of Input Levels

on Page 26)

Right Trim

Allows a +/-3dB adjustment of the right analog audio channel gain to correct minor left/right
balance problems in the input audio. The left channel analog input gain is not affected by this
control and is set using the master Analog Level control previously described.

AES Level (AES/EBU Level)


Adjusts the master audio input level for the AES Digital input which is derived from the rear panel

RJ-45 StudioHUB

®

connector. (See

Proper Setting of Input Levels

on Page 26)

Right Trim

OmniaONE Multicast - Use and Operation Manual – Version 0.90

41