English-24
TagA
Tile Matrix
Tile Matrix demonstrates multiple screens. This feature provides a single large screen
using up to 25 monitors. It will be able to divide up to 5 each H and V.
This requires you to feed the PC output into each of the monitors through a distributor.
ENABLE: Select “ON”, the monitor will expand the selected position.
H MONITOR: Select number of horizontal divide.
V MONITOR: Select number of vertical divide.
MONITOR No: Select a position to expand the screen.
TILE COMP: Works in tandem with Tile Matrix to compensate for the width of the tile
bezels in order to accurately display the image.
Tile Comp with 4 monitors (black area shows monitor frames):
TagB
Date & Time
Adjusts the current date and time for internal clock. You should set this function when you
use “SCHEDULE”.
Daylight Saving: For those timezones where Daylight Saving Time (Summertime)
is observed.
TagC
Schedule
Programs the monitor’s working schedule. Schedule the power on and power off with hour
and a day of the week. Also sets the input port. This OSM can’t remove except EXIT.
Using the “SCHEDULE” function allows you to set up to seven different scheduled time
intervals when the LCD Monitor will be activated.
You can select the time the monitor turns on and turns off, the day of week the monitor is
activated, and which input source the monitor will use for each scheduled activation
period. A check mark in the box next to the number of the schedule indicates that the
selected schedule is in effect.
To select which schedule to set, use the up/down arrows to move the cursor vertically
under the number (1 to 7) of the schedule.
Use the “Down” or “Up” buttons to move the cursor horizontally within the particular
schedule. The “SELECT” button is used to make a selection.
If you create a schedule but do not want to use a power on time, select “--” in the “ON”
time slot.
If you do not want to use a power off time select “--” in the OFF time slot.
If there is no input selected (“-----” showing in the input spot) the input from the previous
schedule will be used.
The selection of EVERY DAY within a schedule takes priority over other schedules that are
set up to operate weekly.
Schedules are numbered 1-7. If two schedules are programmed for the same time, then
the highest numbered schedule has priority. For example schedule #7 will take priority
over schedule #5.
When schedules are overlapping, scheduled Power ON time has priority over scheduled
Power OFF time.
When the “OFF TIMER” is set, the “SCHEDULE” function is disabled.
Before powering off, a message will appear on the screen asking the user if they want to
delay the turn off time by 60 minutes. Press any OSM button to delay the turn off time.
TagD
Eco Mode Information
Displays the estimated power saving information in watt-hours.
TagE
Information
Provides information about the current display resolution Technical data, including the
preset timing currently being used and the horizontal and vertical frequencies is also
displayed.
monitor1
monitor2
monitor3
monitor4
monitor1
monitor2
monitor3
monitor4
Tile Comp ON