Data signal connections, Figure 42. rtsi bus signal connection, Data signal connections -9 – National Instruments DIO 6533 User Manual
Page 52: Figure 4-2, Rtsi bus signal connection -9

Chapter 4
Signal Connections
© National Instruments Corporation
4-9
DIO 6533 User Manual
Figure 4-2. RTSI Bus Signal Connection
♦
PXI-6533—RTSI trigger lines 0 through 6 correspond to PXI trigger bus
lines 0 through 6.
Data Signal Connections
The digital data signals are DIOA<0..7>, DIOB<0..7>, DIOC<0..7>,
and DIOD<0..7>. These data signals are referenced to the GND pins.
Ports DIOA, DIOB, DIOC, and DIOD are port numbers 0, 1, 2, and 3,
respectively.
RTSI Bus or PXI Connector
Crossbar Switch
Trigger
20 MHz Timebase
REQ<1..2>
ACK<1..2>
(STARTTRIG<1..2>)
PCLK<1..2>
DAQ-DIO
STOPTRIG<1..2>
Switch
7
2
2
2
2
See also other documents in the category National Instruments Computer Accessories:
- R Series Intelligent DAQ PXI-784xR (14 pages)
- 7344 (66 pages)
- Relay Module SCC-RLY01 (9 pages)
- Compact FieldPoint Mounting Accessories cFP-21xx (10 pages)
- PCI-4451 (115 pages)
- NI 6239 (172 pages)
- SCXI-1190 (54 pages)
- SCXI-1190/1191 (45 pages)
- NI 785xR (74 pages)
- Multisystem eXtension Interface NI PCIe-836x (37 pages)
- GPIB-BUF (40 pages)
- 6527 (47 pages)
- PCI-8336 (43 pages)
- PXI NI PXI-8105 (73 pages)
- 6025E (136 pages)
- NI 78xxR (12 pages)
- PCI-6110E/6111E (113 pages)
- NI 6115/6120 (127 pages)
- 1128 (97 pages)
- 800 Series (104 pages)
- NI 6115 (127 pages)
- NI 784xR (74 pages)
- GPIB-100A (43 pages)
- VXI-MIO Series (151 pages)
- Low-Cost Multifunction I/O Board for ISA Lab-PC+ (211 pages)
- PC-DIO-24/PnP (107 pages)
- PC-LPM-16/PnP (125 pages)
- NI 7831R (71 pages)
- 653X (147 pages)
- VXI/VME 600 (61 pages)
- PXI NI PXI-1052 (70 pages)
- PC-DIO-96 (105 pages)
- NI UES-3880 (14 pages)
- GPIB-COM (56 pages)
- Switch Executive (8 pages)
- AT-MIO-16X (330 pages)
- 7340 PCI (67 pages)
- NI 783xR (73 pages)
- NI CVS-1450 Series (91 pages)
- SCXI-1321 (16 pages)