beautypg.com

7 units setup, 9 time setup, 8 comms setup – Navman TRACKER 5100I User Manual

Page 30

background image

30

TRACKER 5100/5100i/5500/5500i Installation and Operation Manual

NAVMAN

13-7 Units setup

Distance units

Options are nm (nautical miles), mi (statute miles)
or km (kilometres).

Speed units

Options are kn (knots), mph (miles per hour) or kph
(kilometres per hour).

Depth units

Options are ft (feet), fm (fathoms) or m (metres).

Local offset

The difference between local time and UTC (GMT).
Change local offset when daylight saving time starts
and ends. The range is 0 to ± 13 hours, in 30 minute
steps.

13-9 Time setup

Autopilot out

Disable or enable the NMEA output to an autopilot
or other instrument.

Autopilot data

Displays a list of the NMEA sentences that can be
sent to an autopilot. Turn each Off or On as required.

13-8 Comms setup

Fuel units

Options are litres, US gal (US gallons) or Imp gal
(Imperial gallons).

Compass

The options are °T (True north) or °M (Magnetic
north).

NavBus

Off: NavBus is disabled. One of the NavBus
connector pins becomes a NMEA input line
(see sections 14 and 15-3).

On: NavBus is enabled.

NavBus group

Enter the NavBus backlight group number (the range
is 0 to 4, see section 14).

Time format

The options are 24 hour or 12 hour.

Date format

The options are dd/MMM/yy, MMM/dd/yy,
dd/MM/yy or MM/dd/yy.

To enable the alarm, enter an anchor alarm
distance (up to 9.99 distance units). The
TRACKER saves the current boat position.
To disable the alarm, set the anchor alarm to
Off (0).

The minimum usable setting of the alarm is
determined by the accuracy of the global positioning
system, typically within 10 m (33 ft).

Warning: Do not rely on the anchor alarm as

the only anchor watch.

XTE alarm

When the XTE alarm is enabled, an alarm will sound
when the boat is navigating to a point and the distance
from the boat to the plotted course (XTE) is more
than CDI (Course Deviation Indicator) scale (see
appendix C, CDI).

To enable the alarm, set the XTE alarm to On.
To disable the alarm, set the XTE alarm to Off.

Danger alarm

When the danger alarm is enabled, an alarm will
sound when the boat comes within this distance of a
danger waypoint.

To enable the alarm, enter an danger alarm
distance (up to 9.99 distance units).
To disable the alarm, set the danger alarm to
Off (0).

Low fuel alarm

When the low fuel alarm is enabled, an alarm will
sound when the fuel remaining in the tank is less
than the low fuel value.

To enable the alarm, enter a low fuel value.
To disable the alarm, set the low fuel value to Off.

This manual is related to the following products: