beautypg.com

Sema group sms2000 ois 4.0 and 5.0 – Nokia WAP and SMS gateway User Manual

Page 48

background image

Chapter 5. Setting up a SMS Gateway

Variable

Value

Description

msg-id-type

number

Optional, specifies which

number base the SMSC is using
for the message ID numbers in
the corresponding

submit_sm_resp

and

deliver_sm

PDUs. This is

required to make delivery reports
(DLR) work on SMSC that
behave differently. The number
is a combined set of bit 1 and bit
2 that indicate as follows: bit 1:
type for

submit_sm_resp

, bit

2: type for

deliver_sm

. If the

bit is set then the value is in hex
otherwise in decimal number
base. Which means the following
combinations are possible and
valid: 0x00

deliver_sm

decimal,

submit_sm_resp

decimal; 0x01

deliver_sm

decimal,

submit_sm_resp

hex;

0x02

deliver_sm

hex,

submit_sm_resp

decimal;

0x03

deliver_sm

hex,

submit_sm_resp

hex. In

accordance to the SMPP v3.4
specs the default will be a C
string literal if no of the above
values is explicitly indicated
using the config directive.

alt-charset

string

Defines which character

encoding is used for this specific
smsc link. Uses

iconv()

routines to convert from and to
that specific character set
encoding. See your local
iconv_open(3) manual page for
the supported character
encodings and the type strings
that should be presented for this
directive.

Sema Group SMS2000 OIS 4.0 and 5.0

The 4.0 implementation is over Radio PAD (X.28). Following configuration variables are needed, and if

41